Fujitsu AUXG07KVLA Design & Technical Manual page 260

2-unit multi-split type
Hide thumbs Also See for AUXG07KVLA:
Table of Contents

Advertisement

Indoor unit connect-
Outdoor temperature
ing capacity
kBtu/h
°CDB
-10.0
14
NOTES:
• TC: Total Capacity (kW), IP: Input Power (kW)
• Values mentioned in the table are based on the following conditions:
– Power source of specifications: 230 V
– Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit)
• 2 or more indoor units should be connected.
• The total ability of connected indoor unit is from 14,000 Btu/h up to 26,000 Btu/h.
• Input in the table are calculated based on the maximum indoor unit input combinations.
6-2. Cooling capacity
18.0 °CDB
12.0 °CWB
TC
IP
TC
3.9
0.63
4.4
0.0
3.9
0.82
4.4
5.0
3.9
0.70
4.4
10.0
3.9
0.38
4.4
15.0
3.9
0.51
4.4
20.0
3.9
0.67
4.4
25.0
3.9
0.83
4.4
30.0
3.9
0.97
4.4
35.0
3.9
1.24
4.4
40.0
3.1
1.01
3.5
46.0
3.1
0.78
3.5
Indoor temperature
21.0 °CDB
23.0 °CDB
15.0 °CWB
16.0 °CWB
IP
TC
IP
0.64
4.7
0.65
0.83
4.7
0.84
0.71
4.7
0.71
0.39
4.7
0.39
0.52
4.7
0.52
0.68
4.7
0.69
0.84
4.7
0.85
0.98
4.7
0.99
1.26
4.7
1.27
1.03
3.7
1.04
0.79
3.7
0.80
- 254 -
27.0 °CDB
29.0 °CDB
19.0 °CWB
21.0 °CWB
TC
IP
TC
IP
5.0
0.65
5.3
0.66
5.0
0.85
5.3
0.86
5.0
0.72
5.3
0.73
5.0
0.40
5.3
0.40
5.0
0.53
5.3
0.53
5.0
0.69
5.3
0.70
5.0
0.86
5.3
0.87
5.0
1.00
5.3
1.01
5.0
1.29
5.3
1.30
3.9
1.05
4.2
1.06
3.9
0.81
4.2
0.82
32.0 °CDB
23.0 °CWB
TC
IP
5.5
0.67
5.5
0.86
5.5
0.73
5.5
0.40
5.5
0.54
5.5
0.71
5.5
0.87
5.5
1.02
5.5
1.31
4.3
1.06
4.3
0.82
6. Capacity table

Advertisement

Table of Contents
loading

Table of Contents