 When connecting to Communication kit (for KM models in Wall
mounted type)
When connecting the remote controller to optional Communication kit, follow the procedures men-
tioned below.
1.
Modify the remote controller cable as follows:
• Use a tool to cut off the terminal on the end of the remote controller cable and then remove
the insulation from the cut end of the cable as shown in following figure.
• Connect the remote controller cable and connecting cable as shown in following figure.
• Be sure to insulate the connection between the cables.
2.
Connect the remote controller cable.
• Connect the cable made in step 1. to the terminal*
• Connect the cable from the terminal*
*1:
CNC01 on UTY-TWBXF2
*2:
CND01 on UTY-TWBXF2
Remote controller cable
¢ Required optional parts
Required optional parts for connecting the wired remote controller to the wall mounted type are
as follows.
External connect kit
Communication kit
13-9. Simple remote controller (UTY-RSNYM: Optional part)
Remote controller cable
2
Connecting cable
Part name
Connecting
cable
White
Red
Black
White
Insulated
Red
connection
Black
1
of optional Communication kit.
of Communication kit to the indoor unit PCB.
Terminal
(*2)
Terminal
(*1)
Communication kit
- 163 -
Indoor unit PCB
Model name
UTY-TWBXF2
UTY-XWZXZ5
13. Remote controller