Fujitsu AUXG07KVLA Design & Technical Manual page 120

2-unit multi-split type
Hide thumbs Also See for AUXG07KVLA:
Table of Contents

Advertisement

 Control output function
• Operation/Stop status
Rotary SW on
Function
External input and
setting /
60-00 / 1
The output is low when the unit is stopped.
• Error status
Rotary SW on
Function
External input and
setting /
60-00 / 1
The output is ON when an error is generated for the indoor unit.
• Indoor unit fan operation status
Function
Rotary SW on External
setting /
input and output PCB
60-00 / 1
Output signal
On
Low → High
Off
High → Low
11-2. Wall mounted type (Models: ASYG07KGTB, ASYG09KGTB, ASYG12KGTB,
ASYG14KGTB, ASYG07KETA, ASYG09KETA, ASYG12KETA, ASYG14KETA,
ASYG07KETA-B, ASYG09KETA-B, ASYG12KETA-B, and ASYG14KETA-B)
output PCB
External input and output
Operation
Indoor unit
Stop
On
CN310
Off
output PCB
External input and output
Error
Indoor unit
Normal
On
CN311―312
Off
External input and output
The indoor unit fan is operating.
The fan is stopped or during cold air prevention.
During thermostat off when in dry mode operation.
Fan run
Indoor unit
Fan stop
On
CN311―312
Off
External output
CN310
PCB
External output
CN311
PCB
External output
CN312
PCB
Condition
- 114 -
Output
Command
signal
Off → On
Operation
On → Off
Stop
Output
Command
signal
Off → On
Error
On → Off
Normal
Output
Command
signal
Off → On
Fan run
On → Off
Fan stop
11. External input and output