• Circuit diagram example
Indoor unit
Communication kit
control PCB
– When function setting is "Operation/Stop" mode
– When function setting is "Forced stop" mode
Input signal
Command
Indoor unit
Remote controller
– When function setting is "Operation/Stop" mode 2
Indoor unit
NOTE: When "Operation/Stop" mode 2 function is used with forming a remote controller
group, connect the same equipment to each indoor unit within the group.
11-3. Wall mounted type (Models: ASYG07KMTB, ASYG09KMTB, ASYG12KMTB,
ASYG14KMTB, ASYG07KMCC, ASYG09KMCC, ASYG12KMCC, and ASYG14KMCC)
Connected unit
Example: Switch
Connector
1
3
10 m*
Optional parts
Locally purchased
On
Input signal
Off
Operation
Indoor unit
Stop
On
Off
Forced stop
Normal
Operation
Stop
On
Input
Off
Operation
Stop
(R.C. disabled)
Remote controller
• Contact capacity: DC 24 V or more, 10
mA or more.
• *: Make the distance from the PCB to
the connected unit within 10 m.
• Use non-polar relays and switches.
Signal
On
- 116 -
On
On
On
Remote control
operation invalidity
Off
On
11. External input and output