OWNER/INSTALLATION MANUAL
3�2 PLUMBING
IMPORTANT
Before installing the heat pump ensure the
blanking disks are removed from the pool water
in/out connections� These should drop out when
the adaptors are unscrewed�
1. Ensure that bypass is installed and set to achieve
the recommended flow rates stated in the data
sheet.
2. Ensure that the condensate drain kit supplied is
fixed and is drained to a drain or soak-away.
Water
out
3. Inlet and outlet pipework must be supported to
avoid excessive strain on the connections.
Supported pipework
10
4. Water quality must be maintained as follows:
Water
in
Acidity pH
Total Alkalinity, as CaCO3
Total Hardness, as CaCO3
Total Dissolved Solids
Maximum Salt Content
Free Chlorine Range
Free Chlorine Range
Superchlorination
Bromine
Baquacil
Ozone
Maximum Copper Content ppm
Aquamatic Ionic Purifier
pH
7.2 - 7.8
ppm
80 - 120
ppm
150 - 250
ppm
1000
ppm
35000
ppm
1 - 2 Domestic
ppm
3 - 6 Commercial
max
30ppm for 24 hrs
ppm
2 - 5
ppm
25 - 50
ppm
0.9 Max
1
ppm
2 Max