Prepare For Service; Replace The Control Module - Graco ProBell 24Z221 Instructions And Parts

Air controllers
Table of Contents

Advertisement

Repair
Prepare for
for Service
Service
Prepare
Prepare
for
Service
• To avoid electric shock, remove power from the
system before servicing.
• All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
• Do not substitute or modify system components.
• Read .
NOTICE
NOTICE
NOTICE
To avoid equipment damage, the bearing air must
be on while the turbine is spinning and must not be
turned off until the cup comes to a complete stop.
1. Verify that the cup is not rotating.
2. Close the air shutoff valve on the air controller
air supply line.
3. Unplug the power supply.
24
Replace the
the Control
Control Module
Replace
Replace
the
Control
Follow these instructions to replace the control
module (Refs. 2 and 6). Order Kit 25C423, which
includes the module and the necessary software
token.
1. Follow directions at
2. Label each cable with the number of the
connection port. Disconnect all cables from both
the base module (2) and the cube module (6).
3. Remove the module door (5).
4. Loosen the fasteners (6a) and remove the control
module (6).
5. Remove fasteners (3 and 4), then remove the
base (2).
6. Install the new base (2). Tighten fasteners (3
and 4).
7. Install the new control module (6). Tighten the
fasteners (6a).
8. Reinstall the module door (5).
9. Refer to the labels to reconnect each cable. If
you did not use labels, remove the wire duct
cover. Refer to the schematic and the following
table for connection information.
10. Load the correct software onto the control
module, using the token.
NOTICE
NOTICE
NOTICE
The module will not work if the software is not
installed. See directions in the System Logic
Controller manual (3A3955) for loading the
software.
Module
Module
Prepare for Service, page
3A3954D
24.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Probell 24z222

Table of Contents