64
PERIODIC SERVICE
3. Place the motion control levers in "NEUTRAL LOCK"
position and shut off the engine.
4. Check that the machine does not move.
A For parking brake test purposes, only use 17 ramp.
(A) 17 ramp
BBattery Condition
To avoid the possibility of battery explosion:
For
the
refillable
type
instructions below.
A Do not use or charge the refillable type battery
if the fluid level is below the LOWER (lower limit
level) mark.
Otherwise, the battery component parts may
prematurely deteriorate, which may shorten the
battery's service life or cause an explosion.
Check the fluid level regularly and add distilled
water as required so that the fluid level is
between the UPPER and LOWER levels.
To avoid personal injury:
A Never remove the vent cap while the engine is
running.
A Keep electrolyte away from eyes, hands and
clothes. If you are spattered with it, wash it
away completely with water immediately and
get medical attention.
A Wear eye protection and rubber gloves when
working around battery.
Mishandling the battery shortens the service life and adds
to maintenance costs.
The original battery is a maintenance-free, non-
accessible type battery.
If the battery is weak, the engine will be difficult to start
and the lights will become dim. It is important to check the
battery periodically.
(1) Battery
(2) Ground cable
battery,
follow
the
(+): Positive terminal
(-): Negative terminal