WaterLogic WL380 Troubleshooting Manual page 8

Hide thumbs Also See for WL380:

Advertisement

12. No Water is Dispensing from One Side – Cold or Hot 
 
 
Possible Reason 
Too much water pressure.   
 
Recommend 40 to 60 psi for 
the WL380 Water Treatment 
System to operate properly. 
PCB  
Solenoid  
See "Green Flashing Light" 
Fault Code Section of this 
Manual 
 
 
13. Cold Water Dispenses from Faucet and Vent Outlet Simultaneously 
 
 
Possible Reason 
Improper tubing attachment 
from the Cold Tank to Faucet 
or vice versa 
Scale has formed inside Cold 
Tank outlet tube. 
Expansion chamber in Cold 
Tank is not sealed properly. 
 
 
 
 
WL380 Manual 
Verify water pressure at the Inlet Bulkhead with a Pressure 
Regulator.   
 
Additional method of verification is to turn off water to unit and 
press the Dispense Button.  Does the Solenoid open without water 
pressure to the unit?  Listen for solenoid to activate, not the 
Dispense Button "click". 
 
Adjust water pressure to 40‐60 psi. 
Switch the hot and cold wires on PCB (red and blue connections). 
 
If water now dispenses from the opposite side, this is an indication 
that there is a PCB problem. 
 
Replace PCB 
If both the Water Pressure and PCB have been ruled out, then it is 
the Solenoid. 
 
Replace Solenoid. 
Indicates the Firewall UV system is not detecting adequate dose of 
UV to ensure safe water. 
Verify tubing is connected properly from Cold Tank Outlets to 
correct Faucet attachments. 
Remove Cold Water Outlet Tube from Cold Tank to Faucet.  Pour 
some scale remover into Cold Tank. 
Replace Cold Tank. 
                                                                 Page 49 ‐ Revision:  2‐5‐2018 
Solution 
Solution 