11. Water does not dispense from Unit 
 
 
Possible Reason 
Closed water supply valve 
 
The unit is not properly 
plugged into electrical outlet 
 
Green Heater & Compressor 
Switch button on unit is in the 
off position 
15 Amp Fuse Blown 
Water is present in the Bottom 
Tray, causing the Leak 
Detection to trigger 
Hot and Cold Solenoid 
connections into the Displace 
PCB are loose. 
Exhausted Filter 
 
 
WL380 Manual 
 
Open the water supply valve. 
Check electrical outlet connection, or for blown circuit breaker. 
 
 
Turn Green Heater & Compressor Switch on.   
I = ON 
 
 
Replace the 15 Amp Fuse as needed. 
Remove the Top Cover and Front Panel.  Tip the unit slightly to 
drain, dry Bottom Tray completely. 
Turn power off; unplug the WL380 Water Treatment System and 
visually inspect Solenoid connections into the Display PCB.   Verify 
the soldering points on connections are secure into the board. 
 
Remove the PCB to inspect the front of the board. 
Replace filters as needed. 
 
                                                                 Page 48 ‐ Revision:  2‐5‐2018 
Solution 