WaterLogic WL380 Troubleshooting Manual page 2

Hide thumbs Also See for WL380:

Advertisement

1.  Irregular / Intermittent Dispensing from One Side  
 
 
Possible Reason 
Too much water pressure.  
Recommend 40 to 60 psi for 
the WL380 Water Treatment 
System to operate properly. 
Loose or bad connection on 
the Front Dispensing PCB or 
Solenoid Connector 
Solenoid  
Dispensing button is broken on 
PCB 
 
 
2.  Hot Water Intermittently Forced Out Through the Faucet, or a Dual Stream Out of 
the Faucet 
 
Possible Reason 
Mineral deposits on the 
expansion slot inside the hot 
tank vent chamber which 
blocks the normal path of 
water to expand. 
 
 
 
 
 
 
 
WL380 Manual 
 
Check water pressure at the inlet bulkhead with an accurate 
water pressure gauge.   
 
Additional method of verification is to turn off water to unit and 
press the dispense button.  Does the solenoid open without 
water pressure to the unit?  Listen for solenoid to activate, not 
button "click". 
 
REGULATE input Water Pressure to 40‐60 psi. 
 
Check that they are connected properly and tightened. 
If both the Water Pressure and PCB have been ruled out, then it is 
the Solenoid. 
 
Replace Solenoid. 
Check PCB for loose or damaged button.  Replace PCB as 
necessary. 
 
Descale Hot Tank  
 
See Hot Tank Descaling Instructions that are included further 
below in this Troubleshooting Section. 
 
 
                                                                 Page 43 ‐ Revision:  2‐5‐2018 