9. Hot Water Drip out of Faucet 
 
Possible Reason 
Small Outlet Vent Hole susceptible to scale 
build up. 
WL380 Manual 
Descale Tank.   
 
See Hot Tank Descaling Instructions that are included 
further below in this Troubleshooting Section. 
 
See instructional video on the Partner Area of the 
Waterlogic.com website for more information. 
All Waterlogic Hot Tanks have a built‐in Vent or 
Expansion Chamber in the top of the tank except for 
WL270 (GF) units. 
 
The Vent Chamber allows for expansion of the water 
when it is heated. 
 
The chambers are separated by a welded‐in tank 
baffle. 
 
Water always flows into the bottom of the Hot Tank 
and out the top to the Faucet. 
 
The Hot Tank Outlet Tube has a Restrictor in its base.  
This ensures the reservoir is always full by allowing 
more water in than out. 
 
There is a small hole in the side of the Hot Tank Outlet 
Tube that allows air and water to pass into the Vent 
Chamber as it is heated. 
 
Water in the Vent Chamber is suctioned back through 
the Outlet Tube vent hole when water is dispensed. 
 
Expansion of water as it is heated in the Reservoir will 
push the water out the faucet when the outlet tube 
vent hole becomes plugged with debris or scale.   
 
The small Outlet Vent Hole is susceptible to scale build 
up and is a key indicator that descaling is required. 
 
It is critical to descale the Hot Tank through the vent 
line and outlet line on a regular basis to prevent this 
problem. 
 
 
Descaling through the inlet and/or outlet lines only 
will not clean the vent chamber and outlet vent hole 
properly. 
                                                                 Page 46 ‐ Revision:  2‐5‐2018 
Solution 