17. Run On – Water continues to dispense out of faucet after releasing the dispense 
button 
 
Reason 
"Run On" or "Carry On" is present in all Waterlogic pressure fed units without outlet solenoids. 
 
"Run On" is defined is the amount of water that continues to dispense out of the faucet after 
releasing the dispense button. 
 
Run On exists because the tanks pressurize as water is being dispensed.  Every Waterlogic tank has an 
outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the 
faucet.  The inlet solenoid controls flow into the tanks.  The tanks will "depressurize" once the 
dispense button is released the inlet solenoid closes.  A small amount of water will "Run On" through 
the faucet as the tank depressurizes to atmospheric conditions. 
 
Typical "Run On" is 2‐3 seconds. 
 
"Run On" can be reduced by installing a pressure limiting device. 
 
The amount of inlet or supply pressure directly impacts the amount of "Run On" as quantified below. 
 
WLCP Lab Testing of Run on 7‐31‐2013 
Pressure 
Pressure 
Static PSI 
Dynamic PSI 
68 
50 
32 
Pressure measured at inlet line to unit.  Static with unit closed.  Dynamic with unit 
dispensing cold water. 
No filters were installed in unit. 
 
 
 
 
 
 
WL380 Manual 
Time 
4 Liters 
40 
61 
30 
72 
20 
92 
 
                                                                 Page 51 ‐ Revision:  2‐5‐2018 
Flow Rate 
Run On 
I/min 
Seconds 
2.9508197 
2.5 
1.956217 
2.5 