Viessmann Vitotronic 200 Operating Instructions For The System User page 28

Heat pump control unit
Table of Contents

Advertisement

Central heating/cooling
Setting a time program
Example:
You want to set the same time program
for every day except Monday:
Select the period "Monday–Sunday"
and set the time program.
Then select "Monday" and set the time
program for this.
Note
If you want to cancel the setting early,
press
repeatedly until the required
display appears.
Deleting a time phase
■ Set the time for the end point to the
same time that was set for the start
point
or
■ For the start point, select a time prior
to 00:00 h.
Operating status for heating/cooling
The different operating statuses indicate
how central heating/cooling is imple-
mented via a heating/cooling circuit.
"Standard"
Central heating/cooling is implemented
with the standard room temperature
"Set room temp." (see page 25). The
flow temperature is automatically
matched to the outside temperature.
"Reduced"
Central heating/cooling is implemented
with the reduced room temperature "Set
red. room temp" (see page 25). The
flow temperature is automatically
matched to the outside temperature.
28
(cont.)
The display shows the selected time
phase "- - : - -".
Heating/cooling
0
2
? - -:- - - -:- -
§ - -:- - - - -:- -
Change with
Note
A heating/cooling circuit is not cooled in
the "Reduced" operating status.
"Fixed value"
Central heating takes place with the
max. permissible flow temperature, inde-
pendently of the outside temperature.
Central cooling takes place with the
min. flow temperature, independently of
the outside temperature.
Factory settings:
■ Max. flow temperature for heat-
ing: 60 °C
■ Min. flow temperature for cooling:
10 °C
Mo-Su
4
6
8 10 12 14 16 18 20 22 24
---
u
---
u
HC1
(