2.10 TROUBLESHOOTING THE NETWORK

By following proper troubleshooting procedures you can diagnose and
correct problems with the MCC-16 and those typically encountered with
network installations.

2.10.1 Checking The MCC-16

This section describes how to inspect the MCC-16 to verify proper
operation or isolate problems.
Use the LEDs to determine if the MCC-16 is operating normally.
See
Section 2.4.1
appropriate chapter for each CM, for a complete description of their
LEDs.
Use the LEDs to ensure that you configured the CM(s) as
-
intended. For example, does the 16 Mb LED indicate the CM is
set to the same speed as the ring with which it will interface?
Check the PWR LEDs to verify the reception of power by the
-
CM(s). Resetting CMs with an unlit PWR LED may resolve the
problem.
Check that CMs are securely installed in and fastened to the MCC-16.
If necessary, correctly re-insert each CM.
Be sure that the Token Ring stations and the MCC-16 are adequately
powered in accordance with their respective power-requirement
specifications and are powered on.

2.10.2 Checking Lobe And Station Ports

This section describes how to check lobe and station ports. If problems
are encountered with a station, check the LED(s) associated with the port
to which the station is attached. Consult
solve problems indicated by the LED(s).
2-12
for a description of the MCC-PS LEDs and the
Table 2-3
for actions that may