Cabletron Systems MCC-16 User Manual page 61

Token ring media conversion center
Table of Contents

Advertisement

Table 5-2 Switch Settings For Connecting Cabletron RI/RO Devices
SW1 Settings
1
On - Enable RI port
2
On - Enable RO port
3
On - Enable autowrap on RI (for connection to Cabletron devices)
4
On - Enable autowrap on RO (for connection to Cabletron devices)
Connecting The RI/RO Ports To The RI/RO Ports Of Other Vendors
You must disable autowrap to connect the RI/RO ports to the devices of
other vendors.
Set Switch 1 On and Switch 3 Off to connect the RI of the MCC-CRIO
to the RO of a non-Cabletron device.
Set Switch 2 On and Switch 4 Off to connect the RO of the MCC-CRIO
to the RI of a non-Cabletron device. (See
Table 5-3 Switch Settings For Connecting The MCC-CRIO RI/RO Ports To
SW1 Settings
1
On - Enable RI port
2
On - Enable RO port
3
Off - Disable autowrap on RI (for use with other vendor's devices)
4
Off - Disable autowrap on RO (for use with other vendor's devices)
If autowrap is disabled, connecting a cable to the RI/RO port
!
may cause a beaconing condition before the cable is
completely attached. To avoid this condition connect the cable
CAUTION
before you insert the CM into the MCC-16, or perform the
connection with the MCC-16 shut off.
Other Vendor's Devices
MCC-CRIO SETUP
Table
5-2.)
5-5

Advertisement

Table of Contents
loading

Table of Contents