Troubleshooting Checklist - Enterasys SmartSwitch 6G302-06 Installation Manual

Enterasys smartswitch 6g302-06: install guide
Hide thumbs Also See for SmartSwitch 6G302-06:
Table of Contents

Advertisement

Troubleshooting Checklist

4.2
TROUBLESHOOTING CHECKLIST
If the module is not working properly, refer to
causes, and recommended actions to resolve the problem.
Table 4-2 Troubleshooting Checklist
Problem
All LEDs are
OFF.
No Local
Management
Password screen.
Cannot navigate
beyond Password
screen.
4-4
Troubleshooting
Possible Cause
Loss of power.
Autobaud is enabled, but
the baud rate has not yet
been detected.
Incorrect terminal setup.
Improper console cable
pinouts.
Corrupt firmware image,
or hardware fault.
Improper Community
Names Table.
Table 4-2
for a checklist of problems, possible
Recommended Action
Ensure that the module was installed
properly according to the installation
instructions in
chassis is powered properly.
Press ENTER (RETURN) (may take up to
four times).
Refer to the Matrix E7 Series and
SmartSwitch 6000 Series Modules Local
Management User's Guide for proper setup
procedures.
Refer to
Appendix A
pinouts.
If possible, attempt to download the image to
the module again. Refer to
instructions to clear NVRAM.
1. Refer to the Matrix E7 Series and
SmartSwitch 6000 Series Modules Local
Management User's Guide for the
Community Names Table setup.
2. If the Community Names have been
forgotten, refer to
instructions on how to set the mode switch
to reset the Community Names to their
default values.
Chapter
3, and that the host
for proper COM port
Section B.2
Section B.2
for
for

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6g306-06