CIP Training L5160/L5130
Basic Operation
The clogged nozzle is registered.
12.
Press [Close] 3 times.
13.
Press [Nozzle Recovery].
14.
Press [On].
The clogged nozzle is compensated with another nozzle. Prints with the compensated nozzle
from the first printing job after these settings are configured.
15.
Press [Close].
16.
Press [End].
• It is not reflected in the result of the test print even when [Nozzle Recovery] is set to [On].
When checking the print result in which the clogged nozzle is recovered, print the recovery
check pattern by using the RIP software. For details, see "Functions on the Main Menu", RIP
Settings Guide.
Deleting the Registered Clogged Nozzle
Delete the registered clogged nozzle by nozzle column.
When the clogged nozzle is cleared by performing head cleaning, delete the registered clogged
nozzle. Make sure to switch [Nozzle Recovery] to [Off] after all nozzle defects are cleared.