Installation Sutc919 - Sirius Range Hoods SU906 Installation Instructions Manual

Built-in range hoods
Hide thumbs Also See for SU906:
Table of Contents

Advertisement

Warning!
Before connecting the flexible exhausting
pipe to the motor, make sure the stop valve,
which is on the air outlet of the motor, can
swing.
Exausting version
Connect the flange to the exhausting hole
with an appropriate pipe. Make the electrical
connection through the supply cord.
Filtering version
Connect the flange with a pipe suitable to
convey the air to the top of the cabinet.
Make the electrical connection through the
supply cord.
Rear vented version
All the models with one motor can be rear
vented; if the customer wants to use this op-
tion, it is necessary to remove the 18 screws
from the motor group support. Then take out
the metal support with motor included (Fig.
12). Turn the motor to have the air outlet on
the rear side (Fig. 11) and fix the screws pre-
viously removed1

Installation SUTC919

Remove the grease filters before installing
the product, in order to avoid damage to the
appliance.
Open the glass by rotating it as shown in fig.
13; then remove the grease filters by acting
on their specific handle and rotate them to
remove them from their seating (fig. 14).
Make an opening on the bottom of the
kitchen cabinet having the following sizes:
(fig. 15)
SUTC919 520: 265mm X 498mm - 10"
SUTC919 850: 265mm X 835mm - 10"
SUTC919 27": 265mm X 665mm - 10"
Make sure the cabinet structure and the ma-
terial used allow you to make this opening
without causing any damages, even during
the appliance installation.
Prepare the power supply inside the cabi-
net.
Prepare the air discharge hole for the pro-
duct being installed either in the sucking or
filtering mode.
Use an air discharge pipe whose maximum
length does not exceed 5 meters.
Limit the number of elbows in the piping, as
each elbow reduces the air capacity of the
hood of about 1 linear meter. (Eg.: if you use
no. 2 x 90° elbows, the length of the piping
should not exceed 3 meters).
Avoid abrupt direction changes.
Use a 150mm.
constant diameter pipe for the whole length.
Use piping approved by standards in force.
Remove the fixing screws of the rear steel
bar, as shown in fig. 16.
Rotate the steel bar, including the led bar, to
remove it from its seating (fig. 17 - 18). You
can electrically disconnect the bar by acting
on the specific connector.
13
X 19"
7/16
39/64
X 32"
7/16
7/8
X 26"
7/16
3/16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sutc919Suetc919

Table of Contents