Duct Run Calculation; Electrical; Electrical Supply; Installation - Sirius Range Hoods SIU 404 Installation Instructions Manual

Island
Hide thumbs Also See for SIU 404:
Table of Contents

Advertisement

heaters. To minimize the risk of
drawing these lethal gases back into
the home please follow the heating
equipment manufacturers
standards and guidelines. Refer to
NFPA and ASHRAE for additional
information.

Duct Run Calculation

The maximum duct run before
effecting the performance of the
hood is 100'. Calculate your duct run
by measuring linear feet and adding
the elbows, transitions and caps
E L E C T R I C A L
WARNING: All electrical work must
be
performed
by
a
electrician.
Please ensure that the appropriate
electrical codes or prevailing local
building codes and ordinances are
adhered to.
Ensure that the electricity supply is
disconnected at source. Do not use
an extension cord or adapter plug
with this appliance.
This appliance must be grounded.
Connect to a properly grounded
branch circuit, protected by a 15
amp circuit breaker.
I N S T A L L A T I O N
Structural Preparation for the
Hood Fan Installation
The island hood weighs approxi-
mately 125 lbs. It is therefore im-
perative that a substantial structure
is prepared in the ceiling to attach
the range hood to. Ideally block off
based on the table below.
Maximum Run
6" or 3 1/4 x 10" duct
safety
Deduct
Each 90 elbow used
Each 45 elbow used
Each 6" or 3 1/4 x 10" duct
Transition used
Each 3'1/4 x 10" to 6"
Transition used
Side Wall with damper
Roof Cap

Electrical Supply

qualified
This appliance requires 120V/60Hz,
3amp electrical supply – ensure an
appropriately
completes the electrical hook-up.
The
connection
electrical supply is at the top of the
unit, therefore the electrical supply
must be run down from the ceiling
alongside the ductwork.
All electrical and venting hook-ups
must be in place before commencing
installation of the hood-fan.
an area of at least 12"x12" between
the ceiling joists using 2x4's. Allow
for a hole through the center of this
blocking of at least 6" in diameter
through which to pass the ductwork
and electrical cable.
The underside of the hood must not
be closer than 30" from the cook-top
100 FT
15FT
9FT
1FT
5FT
30FT
30FT
qualified
person
point
for
the
2
2