BEFORE THE INSTALLATION

This models can be used only if connec-
ted with external motors produced by
the same manufacturer.

PANELS OPENING

It is possible to open the steel panels,
which cover the grease filters, by slightly
pulling on a side of the panel itself, as
shown in Fig. 1.
To achieve the complete opening of
panels, you need to release the safety
chains, by using the appropriate spring
catches.
For proper working, it is recommended
to install the appliance at a distance of
2000
- 2100 mm from the floor.
Before starting the appliance installation,
please check that all components are not
damaged, in such a case contact your
retailer and do not carry out installation.

INSTALLATION

Fit a false ceiling with an opening that
has the following dimensions:
SUT950: 1465x965 mm with a minimum
distance of 330 mm between the ceiling
and the false ceiling;
SUT951: 1065x665 mm with a minimum
6
I NST ALL A TION
distance of 330 mm between the ceiling
and the false ceiling.
After having chosen the most suitable po-
sition, prepare the ducting: an air outlet
connection piece, with a diameter of 150
mm to be installed in the side selected, is
provided with the appliance.
Leave any unused exhaust outlets closed.
As shown in fig.2.
Draw the outline of the hole to house the
ceiling-mounted hood on the solid ceiling
as shown in Fig. 3 according to the model
chosen.
Make 4 holes in the ceiling according to the
dimensions as shown in Fig. 4, place the
metric plugs provided in the holes.