A. Manually Muting SIP/Network Failure Alarm Beeps
With the unit connected and powered (Green LED on and Yellow LED off or blinking) it will output 3 beeps every 30
seconds and turn the call LED on and off once per second to indicate a SIP registration failure, failure to receive an
echo reply from pinged gateway or Ethernet connection failure. You can manually disable the beeps by pressing and
holding the "Q" button for 5 seconds (2 beeps will then be heard) or by clicking the "Mute Alarm Until Next Failure"
button in the Viking IP programming software. The LED will continue to flash allowing you to trouble shoot the failure.
B. Connect / Disconnect
Open the "Viking IP Programming" software on the PC and the start screen shown below will appear. Any Viking IP
phones that are connected to the network will appear on the list. Simply select the K-1200-IP Series on the list and
click on the "Connect" button at the bottom or double click the selected phone. If the security code of the selected
phone is still set to default (845464), the PC software will not require entering a security code to connect to the phone.
K-1200-IP Series have a default name of "VIKING_MK64_Vik02", so if many phones are connected to the same network
that all have the default name, MAC addresses must be used to identify each phone.
When finished programming, click on the "Disconnect" button at the bottom. Closing the program will also automatically
disconnect the unit.
(3 beeps repeated every 30 seconds)