Select Time Zone; Daylight Savings - Viking K-1200-IP Series Product Manual

Vandal resistant voip entry phone system with built-in directory and 12 button auto dialer
Table of Contents

Advertisement

13. Wiegand Direction
Wiegand Direction allows you to decide if the 26 bit Wiegand connection will be used as an input or an output. The default
setting for direction is "Inbound" and this is the correct setting if you intend to connect a card reader or Wiegand keypad
device to the wiegand connections.
When the direction is set to "outbound", the 26 bit Wiegand connections become an output and can be connected to the
card reader input on the access control system. Unprogrammed keyless entry codes dialed by the user on the keypad are
then sent over the Wiegand output. When the user dials "#" plus a entry code that is not programmed in the Entry Code
Database, the code dialed by the user is sent over the Weigand output along with the facility code selected. Since Wiegand
data limits the entry code to 65535 maximum, "#" plus entry codes higher than 65535 are not sent over the Wiegand
output. When the user dials "#" plus a valid keyless entry code that is programmed in the Entry Code Database, the code
dialed by the user is not sent over the Wiegand output and the Local / External relay is activated.

14. Select Time Zone

When using date and time logged events or setting the access date and times of keyless codes or proximity cards in
the Entry Code Database, you must program the unit to your time zone. Example: You are installing the K-1200-IP in
the Central standard time zone: Select (UTC - 06:00) CST, which is 6 hours behind Coordinated Universal Time (UTC).
Factory Setting: CST

15. Daylight Savings

The Daylight Savings Time programming can be enabled or disabled and can be programmed to start on any Sunday
in March and stopped on any Sunday in November. Currently, daylight saving time starts on the second Sunday in
March and ends on the first Sunday in November, with the time changes taking place at 2:00AM local time.
Factory Setting: Enabled
16. Relay 1 or 2 Internal / External
With relay 1 and/or 2 set to "Internal" the K-1200-IP will activate its on board relays for doorstrike / gate control. Relay
1 and/or 2 should be set to "External" for higher security installations when using a Viking model RC-4A remote relay
controller to activate the doorstrike / gate controller (see page 21). Note: With relays set to external the internal on
board relays will also activate at the same time as the external relays. Factory Setting: Internal