Viking K-1200-IP Series Product Manual page 22

Vandal resistant voip entry phone system with built-in directory and 12 button auto dialer
Table of Contents

Advertisement

Optional Secure Remote Relay Control Using a Viking Model RC-4A
12V DC Adapter
(included)
Door / Gate Examples:
Door near Entry Phone 1
Relay 1 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Doorstrike,
120V AC
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
Connectors (included)
Gate near Entry Phone 2
Relay 2 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Gate Controller, etc.
Gate Controller
(Power typically not
required for gate controllers)
Door near Entry Phone 3
Relay 3 Output Contacts
(5A@30VDC / 250VAC max)
120V AC
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
2 Gel-Filled Butt
Connectors (included)
The front panel of the K-1200-IP is mounted using security Torx screws to help prevent intruders from removing the panel
and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model
RC-4A remote relay controller can be used. The relay controller is mounted securely inside the building and connected to
the same LAN as the K-1200-IP. The on board door strike relays would not be used in this case as the K-1200-IP will send
an encrypted message to the RC-4A to activate its relays which control the door strikes/gates. For more information, see
DOD# 582 at www.VikingElectronics.com.
Up to 4 K-1200-IP's can communicate with one RC-4A allowing you to securely control four entrances.
When using an RC-4A for remote relay control the K-1200-IP's relays should be set to "External" in the PC programming.
Note: If the K-1200-IP loses communications with the RC-4A, the LED on the front panel of the K-1200-IP will flash 3 times
every 2 seconds indicating the communication error. If this error occurs, make sure the RC-4A is powered, has a network
connection and has the correct IP address and security code of the K-1200-IP displaying errors.
VIKING
RELAY CONTROLLER
IN1 C IN2 IN3 C IN4
RELAY 1
RELAY 2
1
2
3
4
5
LED 1
LED 2
COM.
N.O.
2 Gel-Filled Butt
COM.
N.O.
2 Gel-Filled Butt
Connectors (included)
COM.
N.O.
MODEL RC-4A
©
VIKING
ELECTRONICS
HUDSON, WI 54016
NETWORK ENABLED
1
2
3
4
5
6
STATUS
LED
RELAY 3
RELAY 4
LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
SPARE
6
7
8
9 10 11 12
1 2 3 4
NETWORK
LED 9
LED 6
LED 7
LED 5
LED 8
LED 3
LED 4
on
1
2
3
4
Sensor
Examples:
Door Sensor
Gate Sensor
Door Sensor
Door Sensor
Door near Entry Phone 4
Relay 4 Output Contacts
250VAC max) Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Connectors (included)
22
SIP VoIP PBX,
SIP Cloud based
Service Provider
Switch
or
PC with SIP
Server Software
PoE
Switch
IN1 C IN2 IN3 C IN4
1
2 3 4 5 6
(5A@30VDC /
COM.
Doorstrike /
N.O.
Magnetic Lock
2 Gel-Filled Butt
Internet
K-1200-IP
Entry Phone 1
K-1200-IP
Entry Phone 2
K-1200-IP
Entry Phone 3
K-1200-IP
Entry Phone 4
120V AC

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-1200-ipK-1200-ip-ewp