Integrated DC
General data
disconnector
Product name
Rated insulation
voltage
Rated impulse with-
stand voltage
Suitability for isolation
Utilization category
and/or PV utilization
category
Rated short-time with-
stand current (I
Rated short-circuit
making capacity (I
Rated operational current and rated breaking capacity
Rated operational
voltage (U
≤ 500 V
600 V
700 V
800 V
900 V
1000 V
Number of poles
The values stated are defaults; the inverter is configured specifically to suit the
requirements of the relevant country.
Depending on the country setup or device-specific settings
(ind. = inductive; cap. = capacitive).
Maximum current from a defective PV module to all other PV modules. From the
inverter itself to the PV side of the inverter it is 0 A.
Guaranteed by the electrical configuration of the inverter
For backup power mode (PV Point) without battery, a minimum voltage of 150 V
is required.
Current peak when switching on the inverter.
according to IEC/EN 60947-3 Category of utilization DC-PV2
)
cw
)
cm
Rated operational
)
current (I
e
DC
DC
DC
DC
DC
DC
Output on the changeover contact
IEC 61643-31 / DIN EN 50539-11
UL1449 ed.4 / VDE 0185-305-3 Bbl. 5
Rated short-time withstand current (I
Rated short-circuit making capacity (I
I
/
rated operational
(make)
)
current (I
I
e
(break)
14 A
56 A
8 A
32 A
3 A
12 A
3 A
12 A
2 A
8 A
2 A
8 A
1
1
Thermoplastic UL-94-V0
Benedict LS32 E 7905
1000 V
DC
8 kV
Yes, DC only
): 1000 A
cw
): 1000 A
cm
I
/
(make)
)
I
e
(break)
36 A
144 A
30 A
120 A
26 A
88 A
17 A
68 A
12 A
48 A
6 A
24 A
2
2