Settings on the Fronius Symo GEN24 inverter website:
Configure the primary meter at the feed-in point in the "Device configuration" →
1
"Components" menu.
Settings in the system monitoring of the Fronius SnapInverter:
Configure the primary meter at the feed-in point in the "Settings " → "Meter" menu.
1
Activate the limit for the entire system in the "DNO Editor" → "Dynamic power reduc-
2
tion" menu. Enter the DC nominal output of the entire PV system in the "Total DC
system power" input field. Enter the percentage value (50%, 60% or 70%) in the
"Max. grid feed-in power" input field.
Example 2b: Fronius SnapINverter > Fronius Symo GEN24
Two primary meters and one secondary meter are required for the inverters.
The power values shown are an example. Inverter configurations with power values oth-
er than those shown in the example are possible, taking into account the criteria for this
example.
IMPORTANT!
In order to be able to record all PV system data in Solar.web in full, only the Fronius
Symo GEN24 inverter may be created in this PV system. The Fronius SnapINverter data
is transmitted from the secondary meter to the Fronius Symo GEN24 inverter and thus
displayed in the Solar.web.
We recommend that you set up the Fronius SnapINverter as a separate additional PV
system in Solar.web for servicing and maintenance work (e.g. status codes, online up-
dates, etc.).