Connecting the inverter to the public grid (AC side)

Safety

Danger due to incorrect operation and incorrectly performed work.
This can result in serious injury and damage to property.
Danger due to grid voltage and DC voltage from solar modules that are exposed to
light.
An electric shock can be fatal.
Danger due to damaged and/or contaminated terminals.
This can result in serious injury and damage to property.
Connecting the
NOTE!
inverter to the
public grid (AC
The neutral conductor must be connected in order to operate the inverter.
side)
It is not possible to operate the inverter in unearthed grids, such as IT grids (insulated
grids without ground conductor).
IMPORTANT!
The ground conductor of the AC cable must be laid in such a way that it is the last to be
disconnected in the event that the strain-relief device should fail.
This can be ensured by making it somewhat longer and by laying it in a loop.
1
48
WARNING!
Read the Installation and Operating Instructions before installing and commissioning
the equipment.
Only qualified personnel are authorised to commission your inverter and only within
the scope of the respective technical regulations.
WARNING!
Prior to any connection work, disconnect the inverter on the AC side and the DC
side.
Only an authorised electrical engineer is permitted to connect this equipment to the
public grid.
WARNING!
Before making any connections, check the terminals for damage and contamination.
Remove contamination in the de-energized state.
Have defective terminals repaired by an authorised specialist.
Make sure that the grid's neutral conductor is grounded.
Turn off the automatic circuit breaker.