Download Print this page

Blizzard 810SS Assembly & Operation Manual page 45

Snowplow

Advertisement

Problem
Wing will not move.
Plow will not angle.
Should your snowplow develop other problems not indicated in the Troubleshooting Guide, contact your local dealer for technical assistance and/or replacement parts.
Technical support can also be obtained by calling our Customer Service Department toll free at 1-888-680-8600, Monday - Friday, 8AM - 5PM EST.
Wing Pressure Relief Valves
Angle Pressure Relief Valves
S10
S9
RV
RV
RV
S4
L-WINGEXT
L-SLDRET
S3
Probable Cause(s)
Control station, wire harness or cables may be loose or
improperly connected.
No power to the cartridge valve.
Coils are receiving power.
Cartridge valve may be contaminated or damaged.
A bent cartridge will not allow the valve to move freely
inside of the cartridge.
Review all probable causes above.
RV
DS
S2
S1
R-WINGEXT
R-SLDRET
RV
Crown Nut
Jam Nut
Valve
FR
ORIFICE-2
LE
Suggested Remedy
Verify control station, wire harness and all cables are
securely connected. Clean if necessary.
Verify S1 & S2 coils (passenger's side slide box
retract and extend) and S9 & S10 (driver's side slide
box retract and extend) are connected properly.
Diagnose the wire harness. Review all wire harness
schematics. If power is present, review the next step.
Verify that the coils are magnetizing. Position a screw-
driver inside of the coil. When the respective function is
activated, the screwdriver is drawn to the side of the coil.
If the coil is not drawn to the screwdriver, replace the
coil. If power is present, review the next step.
Determine a damaged cartridge valve by reversing the
driver's side and passenger's side cartridge valves.
Replace valve if necessary.
NOTE: Verify coils S3 & S4 for angle functions.
Troubleshooting Guide (2 of 2) 43

Advertisement

loading