6.5.27 Configure trust center connection key

Read command format:
Command format
Send: FE 10 38 FF
Return: FB 38 TrustCentLinkKey
Configuration command format:
Command format
Send:FD 10 38 TrustCentLinkKey FF
Return:FA 38
TrustCentLinkKey: 16 bytes, default is: the default key of ZigBee Alliance, the value is:
Note: only the network access device with the same Linkkey as the Trust Center (Coordinator) can connect to the
network of the Trust Center (Coordinator). At the same time, the Trust Center (Coordinator) transmits the network key to
the network access device, and the network access device completes the network access process, obtains the network key
for normal communication.

6.5.28 Firmware version command description

Read command format:
Command format
Send: FE 03 34 FF
Return: FB 34 FirmwareVersion
Firmware_version: 82 58 00
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd.
29
Command example
Send: FE 10 38 FF
Return: FB 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
Command example
Send:FD 10 38
Return:FA 38
0x5A 0x69 0x67 0x42 0x65 0x65 0x41 0x6C
0x6C 0x69 0x61 0x6E 0x63 0x65 0x30 0x39
Device restart takes effect.
Command example
Send: FE 03 34 FF
Return: FB 34 82 58 00
82 58 is Telink's 8258 chip
00 is firmware version
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39