When non sleep terminal device receives data, it can analyze the long address of coordinator, router, terminal and other
source equipment, but coordinator and router cannot analyze the long address of source equipment. Here coordinator and
router are E180-ZG120A/B devices.
Note: The maximum packet length supported by the transmitter is 72 bytes.
6.5.3 Network node type
Read command format:
Command format
Send: FE 01 01 FF
Return: FB 01 dev_type
Configuration command format:
Command format
Send:FD 01 01 dev_type FF
Return:FA 01
Dev_type:
The configuration of the changed node type will take effect after restart. If the node type is configured in normal
operation, the device will leave the current network and be in no network state. After restart, it will switch to the
changed node type. Sleep terminal supports serial port pin wake-up function, wake-up frame byte length is less than
or equal to 5 bytes, it is recommended to use "FF FF FF FF FF" wake-up.
6.5.4 Network status
Read command format:
Command format
Send: FE 01 02 FF
Return: FB 02 nwk_state
Nwk_state:
6.5.5 Network PAN_ID
Read command format:
Command format
Send: FE 02 03 FF
Return: FB 03 pan_id
Configuration command format:
Command format
Send:FD 02 03 pan_id FF
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd.
19
Command example
Send: FE 01 01 FF
Return: FB 01 03
Command example
Send:FD 01 01 03 FF
Return:FA 01
0x03 Terminal (default)
0x04 Sleep terminal
Command example
Send: FE 01 02 FF
Return: FB 02 02
0x00 No network
0x02 Has joined the network
0x03 Has network but no parent node
Command example
Send: FE 02 03 FF
Return: FB 03 FE 5B
Command example
Send:FD 02 03 FE 5B FF