Hex Parameter Description; System Transmission Mode; Receiving Data Output Mode - Ebyte E180-Z5812SP User Manual

2.4 ghz zigbee multifunctional soc wireless module
Hide thumbs Also See for E180-Z5812SP:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co., Ltd.

6.5 HEX parameter description

6.5.1 System transmission mode

Read command format:
Command format
Send: FE 01 26 FF
Return: FB 26 send_mode
Configuration command format:
Command format
Send:FD 01 26 mode FF
Return:FA 26
Mode:
configuration mode first)
configuration mode first)
short address of the target device)
number)

6.5.2 Receiving data output mode

Read command format:
Command format
Send: FE 01 27 FF
Return: FB 27 out_mode
Configuration command format:
Command format
Send:FD 01 27 mode FF
Return:FA 27
Mode:
Note: When sleep terminal equipment receives data, it does not support to analyze the long address of source device.
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co.,Ltd.
18
Command example
Send: FE 01 26 FF
Return: FB 26 02
Command example
Send:FD 01 26 02 FF
Return:FA 26
0x00 Broadcast (Default)
0x01 Multicast (It needs to configure target group number in configuration mode first)
0x02 Transparent unicast+short address (It needs to configure the target short address in
0x03 Transparent unicast+long address (It needs to configure the target long address in
0x04 Protocol unicast+short address (In transmission mode, the first two bytes are the network
0x05 Protocol multicast (In transmission mode, the first byte is the target network group
Command example
Send: FE 01 27 FF
Return: FB 27 00
Command example
Send:FD 01 27 00 FF
Return:FA 26
0x00 Transparent transmission (default)
0x01 Data+short address
0x02 Data+long address
0x03 Data+RSSI
0x04 Data+short address+RSSI
0x05 Data+long address+RSSI
E180-Z5812SP User Manual