Kyoto Kagaku MW60 Instruction Manual

Kyoto Kagaku MW60 Instruction Manual

Tracheostomy simulator

Advertisement

Quick Links

MW60
Tracheostomy Simulator
Do not mark on the model and other
Caution
components with pen nor leave printed
materials contacted on surface.
Ink marks on the models cannot be
removed.
Instruction
Manual
Contents
● Features and Cautions・・・・・・・・P.1
● Before use ・・・・・・・・・・・・・P.2
● Preparation
Setup and fixation of skins・・・・・P.3
● Training
for tracheostomy・・・・・・・・・・P.4
● After training
Storage ・・・・・・・・・・・・・・・P.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MW60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kyoto Kagaku MW60

  • Page 1 Do not mark on the model and other Caution components with pen nor leave printed materials contacted on surface. Ink marks on the models cannot be removed. MW60 Tracheostomy Simulator Instruction Manual Contents ● Features and Cautions・・・・・・・・P.1 ● Before use ・・・・・・・・・・・・・P.2 ●...
  • Page 2 Before use Features and cautions Manufacturer's note Thank you for purchasing MW60 Tracheostomy Simulator. This is the training model which can practice puncture/incision of cricothyroid ligament. Please use this as training model for medical education. Please read Please do not use this model outside of it's original purpose. Please be reminded that the manufacturer is not responsible for the unlikely damage or accidents by the way of use not written in this instruction.
  • Page 3 Before use Before use Set includes Before you start, please ensure that you have all components listed below. a) Main Body・・・・・・・・・・・・・ 1 b) Cricoid cartilage・・・・・・・・・・・・・・・・1(Preset) c) Skin for tracheostomy / ・・・・・・・・・・・・・・3 d) Subcutaneous tissue for trachesotomy・・・・・・・・・・3 (1 preset) e) Instruction manual...
  • Page 4 Preparation Setup and fixation of skins Setup 1. Attach the skin for tracheostomy to the subcutaneous tissue. Please adjust the center of the skin to the center of main body. *There is no front and back side of the skin. 2.
  • Page 5 Confirmation of catheter position Training Exchange of Skin and Subcutaneous tissue for tracheostomy Confirmation of catheter position 1. Accurate insertion of catheter can be confirmed by visually checking the catheter position. Opening for confirmation Exchange of Skin and Subcutaneous tissue Exchange of skin The skin for tracheostomy can be repetitively used by...
  • Page 6 Storage After training Storage After training, detach the skin from the main body and store. If the skin is left attached to the main body, the tension of the skin will change which may affect the effectiveness of training. Skin for tracheostomy...
  • Page 7 Do not mark on the model and other Caution components with pen nor leave printed materials contacted on surface. Ink marks on the models cannot be removed. Code number part Replacement  Skin for tracheostomy   (set of 3) 11442-010 part 11442-020 Subcutaneous tissue for tracheostomy  (set of 3) Skin for tracheostomy Subcutaneous tissue for   (set of 3) tracheostomy (set of 3) 2021/01...