Perineorrhaphy simulator

Advertisement

Quick Links

MW37
Perineorrhaphy Simulator
Do not mark on the model and other components
Caution
with pen nor leave printed materials contacted
on surface.
Ink marks on the models cannot be removed.
Instruction 
Manual
Contents
● 
Manufacturerʼs Note
● 
● 
● 
P.1
P.2
P.3
P.4

Advertisement

loading
Need help?

Need help?

Do you have a question about the MW37 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kyoto Kagaku MW37

  • Page 1: Table Of Contents

    Do not mark on the model and other components Caution with pen nor leave printed materials contacted on surface. Ink marks on the models cannot be removed. MW37 Perineorrhaphy Simulator Instruction  Manual Contents Introduction P.1 ●  Manufacturerʼs Note P.2 Before You Start ●   Set Includes/ Precautions Training P.3...
  • Page 3: Introduction

    Introduction  Manufacturerʼs Note Perineorrhaphy Simulator has been developed for advancing the skills in Midwifery,  and facilitates the training in Perineorrhaphy. ■ Features ○  Suture training of the first-degree perineal tear. ○ Genital area excels in elasticity, durability and resilience to provide multiple training opportunity. ■ Training skills ● Perineorrhaphy ・Single interrupted suture ・Vertical mattress suture Read before use This simulator has been developed for the training of medical and paramedical professionals only.  Any other use, or any use not in accordance with the enclosed instructions, is strongly discouraged.  The manufacturer cannot be held responsible for any accident or damage resulting from such use.  Please use this model carefully and refrain from subjecting to any unnecessary stress or wear.  Should you have any questions on this simulator, please feel free to contact our distributor  in your area or KYOTO KAGAKU at any time. (Our contact address is on the back cover of this manual)
  • Page 4: Before You Start

    Before You Start  Set Includes/ Precautions Set Includes Before you start, ensure that you have all components listed below. a. genitalia skin c. talcum powder b. supporting holder 1  instruction manual DO s and DON Ts ʼ  ʼ  ● Handle the manikin and the components  ● Do not let ink from pens, newspapers,  with care. this manual or other sources contact  Be sure not to drop or add shock to the manikin  with the manikin, as they cannot be  and its components, since the product uses  cleaned off the manikin skin. special resins and heavy, such shock may cause  damage to the products or environment. ● Storage in a dark, cool and dry space  ● Never use organic solvent like paint  will help prevent the skin colors  thinner or alcohol to clean the skin,  from fading and product from deforming. as this will damage the simulator. ● The manikin skin may be cleaned  ● Even if color on its surface might be  with a wet cloth if necessary, using  changed across the ages, this does not  mildly soapy water or diluted detergent. affect the quality of its performance. 2...
  • Page 5 Cautions for storage method and  Before You Start handling of genitalia skin. PLEASE READ : ■ Always follow the handling and storage instruction below, to keep the material  with its elasticity and durability. AFTER USE: Apply talcum powder on the genitalia skin, put on the supporting holder,  cover them with included transparent bag and store them in the storage box. ○ Do not let the parts contact with other resin items and printed materials. These soft material of the parts may be deformed by contact with other resin items and marked  by contact with printed material and they cannot be repaired. ○ Maintain proper temperature, humidity and avoid direct sunlight of the storage        room of simulators. Be sure to monitor the indication sticker on the storage box of the product. Store the simulator below 60 degrees C. Change the storage place immediately when the temperature indicator shows color circles as below. ※The color circles are irreversible. Before turned After turned 3F65 年 月貼付 3F65 年 月貼付 3...
  • Page 6: Training

    Original Packaging Training Training Original Packaging 1.Take out the simulator from the storage box. The main unit is packed in the storage bag. ※Do not dispose this bag.   It is necessary for storage. The talcum powder and  the puff are stored under  the main unit. Training Take out the main unit from  the storage bag to practice  Perineorrhaphy. ● Perineorrhaphy ・Single interrupted suture ・Vertical mattress suture 4...
  • Page 7: After Training

    Replacement of the Genitalia Skin After training After Training Replacement of the Genitalia Skin 1. Put the finger into the gap between the genitalia skin and the holder to remove it, and attach   the new skin. Put the genitalia skin into the pit of the supporting holder. Apply the talcum powder   on the edge of skin to make it easy.  Put the skin from directions to the holder. Ensure that   the skin is sitting in the holder firmly. ※The replacement genitalia skin   (a set of two) are stored one of   each in the storage bag. Storage bag After Training If the genitalia skin gets dirty after training, clean by wiping with soap or neutral detergent, and  apply the talcum powder on it to store on the supporting holder putting in the storage bag definitely. ※Never use organic solvent   like paint thinner or alcohol   to clean the skin, as this   will damage the skin and   the supporting holder. ※The genitalia skin is made of the special material which is optimal for the suture training.   If this skin is stored in contact with other resin products for a long time, the part might be deformed,   or cause deterioration in the contacted resin products. 5...
  • Page 8 Parts (needle forceps, tweezers, scissors, needle, strings)  For inquiries and service, please contact your distributor or KYOTO KAGAKU CO., LTD. The contents of the instruction manual are subject to change without prior notice. No part of this instruction manual may be reproduced or transmitted in any form without permission from the manufacturer.
  • Page 9 モデル表面に印刷物などが直接触れないよう にしてください。 樹脂表面にインクが吸収されて消えなくなります。 MW37 会陰裂傷縫合モデル 取扱説明書 目 次 はじめに P.1 ●   製品の特長とご注意 P.2 ご使用の前に ●  セット内容・ご使用上の注意 実 習 P.3 ●  後片付け他 P.4 ● ...
  • Page 11 はじめに  製品の特長とご注意  このたびは当社の「会陰裂傷縫合モデル」をお買い上げいただき、誠にありがとうございます。 本製品は助産技術の向上を目的に開発されたモデルです。会陰部裂傷縫合の実習教材として ご使用ください。 ■ 特 長 ○  会陰裂傷第1度を想定した縫合法トレーニングモデルです ○ 外陰部に、 伸縮性、 耐久性に優れた新素材を採用する事で繰り返し縫合トレーニングが行えます ■ 実習項目 ● 会陰裂傷縫合法 ・単一結節縫合 ・垂直マットレス縫合 必ずお読みください  本来の使用目的以外にはご使用にならないでください。また取扱説明書に記載された方法以外での ご使用による万一の破損や事故に関して、当社は責任を負いかねますのでご了承ください。...
  • Page 12 ご使用の前に  セット内容・使用上のご注意  セット内容 ご使用の前に、 構成品が全て揃っているかご確認く ださい。 a. 外陰部皮膚 c. タルカムパウダー      ( パフ付) b. 支持台    取扱説明書 ● 取り扱いにご注意ください。 ● ボールペンやサインペンで書き込まない   でください。 特殊軟質樹脂を使用しておりますので、落下や圧迫 を加えると変形や破損の原因となります。 サインペン、ボールペンなどでモデルに書き込む と、インクが吸収されて消えなくなります。 ● 印刷物をモデル表面におかないでください。 ● 表面が変色する場合があります。 表面に印刷物などが直接触れないようにしてくだ 長期間使用されない場合や経年変化で変色するこ さい。 とがありますが、ご使用には差し支えありません。 ● 高温多湿を避けて保管してください。 使用後は、高温多湿や直射日光のあたる場所での 保管は避けてください。 変形や故障の原因となります。 2...
  • Page 13 ご使用の前に 外陰部皮膚の取扱い及び保管方法に関するご注意 必ずお読みください! ■ 外陰部皮膚の取扱い及び保管方法に関するご注意 外陰部皮膚には伸縮性と復元性、耐久性に優れた特殊な軟質樹脂を使用しております。 下記の注意事項を必ずお読みいただき、適切な取扱いと実習後の保管をお願いいたします。 ○ 実習後は外陰部皮膚は支持台に取り付け、付属の透明袋に入れ、梱包時の箱に収納の上   保管してください。   ○ 他の樹脂製品や印刷物が外陰部皮膚に直接触れないようにしてください。 他の樹脂製品や印刷物が直接外陰部皮膚に接触した状態で保管されますと、表面に型が残ったり 印刷物のインクが吸収され、消えなくなる場合があります。 ○ 適切な温度・湿度で、直射日光を避けて保管してください。 外箱に適切な保管温度の目安となる警告用シールが貼付してあります。 気温が 60℃以下の場所で保管してください。 65℃以上になると左端の○印のマークが黒色に変色しますので、すみやかに保管場所を移動して ください。 ※1度変色したシールは元の色に戻りません。 発色前 発色後 3F65 年 月貼付 3F65 年 月貼付 3...
  • Page 14 納品時の収納状態 実 習 実 習 納品時の収納状態 1. モデル本体を収納ケースから引き出します。モデル本体は透明の収納袋に入っています。 ※収納袋は収納時に必要です  ので、捨てないようにして  ください。 モデル本体の下にタルカム パウダーとパフが入ってい ます。 実 習 モデル本体を収納袋から取り出し 会陰裂傷縫合の実習を行います。 ● 会陰裂傷縫合法 ・単一結節縫合 ・垂直マットレス縫合 4...
  • Page 15 外陰部皮膚の交換 後片付け他 後片付け 外陰部皮膚の交換 1. 支持台と外陰部皮膚の隙間に指を差し込んで取り外し、新しい皮膚を取り付けます。 支持台の凹み部分に外陰部皮膚を挿入します。外陰部皮膚の挿入部分にタルカムパウダーを塗布すると 挿入しやすくなります。どの部分から入れてもかまいませんが、本体と皮膚がなじむようにしっかり 挿入してください。 ※交換部品の外陰部皮膚 (2 枚組 ) は  それぞれ専用の収納袋に入ってます。  必ず収納袋に入れて保管してくだ 専用収納袋  さい。 後片付け 実習後は外陰部皮膚に汚れがあれば水又は中性洗剤で拭き取り、タルカムパウダーを塗布して支持台に 取り付け、必ず収納袋に入れて保管してください。 ※アルコールやシンナーなど  の有機溶剤は、絶対に使用  しないでください。  支持台は表面が劣化します  ので、拭き取らないでくだ  さい。 ※外陰部皮膚は縫合実習に適した特殊樹脂を使用しています。  直接他の樹脂に長時間触れた状態で保管されますと変形したり、他の樹脂が劣化する恐れがあります。 5...
  • Page 16 モデル表面に印刷物などが直接触れないようにしてください。 樹脂表面にインクが吸収されて消えなくなります。 交換部品 コード 品 名 11417-010     外陰部皮膚2枚組 (会陰縫合用) 外陰部皮膚2枚組 (会陰縫合用) コード 品 名 別売品 会陰縫合器具セッ ト 11417-030  (持針器・ピンセット・ハサミ・針・糸) ・ご不明な点は、お買い上げの販売店、もしくは下記(株) 京都科学まで御連絡ください。 http://www.kyotokagaku.com ■ 本社・工場 ■ 東京支店 〒612-8388 京都市伏見区北寝小屋町15番地 〒113-0033 東京都文京区本郷三丁目26番6号 TEL:075-605-2510(直通) NREG本郷三丁目ビル2階 FAX:075-605-2519 TEL:03-3817-8071(直通) FAX:03-3817-8075 2018.04...