Program Add & Manage; Run Program For Charger - iCharger 308DUO User Manual

Synchronous balance charger/discharger
Table of Contents

Advertisement

 Program Add & Manage
Click STOP/START-x button on the initial interface to pop up the BATTERY MEMORY SELECT window.
308DUO has 7 built-in programs before it enters to the market (shown in the following picture), which cannot be deleted
and are limited for editing. The built-in programs are underline to distinguish them from the customized programs set by
the user.
Click "
" (or long press KNOB) to pop up the MANAGE after exiting focus via pressing TAB/SYS, and click
"
" to enter MEMORY SETUP to edit the program, or click "
enter its editing interface at the same time.
Note: If the program selected is a built-in program, "Copy From..." and "Delete" options are shown in
grey as inactive status, and unable to be set.
 Run Program for Charger
After selecting program on BATTERY MEMORY SELECTION, click to enter Run Program interface (long press
STOP/START-x button on the initial interface will enter Run Program from the last running program), as below:
1
Note: 1. The revised common parameters of built-in program will be saved by default automatically
after running, while the program customized by the user can be set to be saved or not in
MEMORY SETUP→MEMORY OPTION→Auto save before the program runs.
2. After setting the Cap. value, when the Current value exceeds the certain value, the system will
be a warning display and alarm voice(shown in the following picture). The Current value of
each battery type is: LiXX battery :> 3C, NiMH/NiCd battery :> 2C, Pb battery :> 0.3C, NiZn
battery>2C.
Synchronous Balance Charger/Discharger
1: Run Program Selection
2
2: Common Parameters Setup
3. Auto- save Hint
3
- 13 -
308DUO V1.1.0