Comtrol ROCKETLINX ES8510 Quick Installation Manual page 4

Table of Contents

Advertisement

The power input voltage
of logic low is 0 to 10VDC
and logic high is 11 to
30VDC. Do not apply a
higher voltage than the
specification; it may cause
internal circuit damage
or cause an incorrect DI
action.
Digital output relay contacts are energized (open) for normal operation and
close for fault conditions. The digital output relay contacts support up to 1A
at 24VDC. Do not apply voltage and current higher than the specifications.
1.
Insert the positive and negative wires (12-24 AWG) into V+ and V-.
2.
Tighten the wire-clamp screws to prevent the wires from coming loose.
Mounting the ES8510
You can mount the ES8510 onto a DIN rail or optionally a panel or wall.
Follow the steps below to install the ES8510 with the
wall mounting plate:
1.
To remove the DIN rail clip from the ES8510,
loosen the screws from the DIN rail clip.
2.
Place the wall mounting plate on the rear
panel of the ES8510.
3.
Use the screws to attach the wall mounting
plate to the ES8510.
4.
Use the hook holes at the corners of the wall
mounting plate to hang the ES8510 onto the wall.
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rocketlinx es8510-xtRocketlinx es8510-xte

Table of Contents