12.2 Checking Safety Circuit Design

12.2.1 Safety Circuit Design

Example of a safety circuit
Be sure to create a safety circuit when using this product.
Installation of over limit switches
● Install over limit switches as shown above.
● Connect them to the CW and CCW over-travel inhibit inputs of the parallel I/O connector of
the servo amplifier. For the GM1 Controller, connect them to the limit input (+) and limit input
(-) through the network.
● Install the safety circuit recommended by the manufacturer of the motor being used.
WUME-GM1RTXSU-01