Chapter Objectives
Catalog Number:
Environmental:
Operating Temperature
Storage Temperature
Electrical:
Input Voltage
Input Frequency
Input Current
SCANport Load
Communications:
SCANport Side
Serial Side
Baud Rates
Checksum
Dimensions:
Module Compatibility
Specifications
This chapter provides you with background information and
specifications that you may need to install or apply your Serial
Communications Module.
Product Specifications
Enclosed Style 115/230V
Open Style
–GM2
0 to 50 C (32 to 122 F)
–40 to 85 C (–40 to 185 F)
–40 to 85 C (–40 to 185 F)
Supplied by drive
NA
NA
60mA DC
SCANport Peripheral
Interface
RS–232/RS–422/RS–485
(DF1)
DH–485
110, 300, 600, 1200, 2400,
110, 300, 600, 1200, 2400,
4800, 9600, 19.2K
BCC or CRC
Open (IP00)
NA
This module is intended for use with devices that communicate via
RS–232, RS–422, or RS–485 hardware standards using the DF1
protocol or the DH–485 standard. The Serial Communications
Module is intended to provide a means for transmitting messages
between these serial communications devices and Allen-Bradley
SCANport devices.
Enclosed Style 24V DC
AC
–GD2
0 to 50 C (32 to 122 F)
0 to 50 C (32 to 122 F)
–40 to 85 C (–40 to 185 F)
85 to 264V AC, 1 phase
45 to 63 Hz
35mA maximum
60mA DC
SCANport Peripheral
Interface
RS–232/RS–422/RS–485
RS–232/RS–422/RS–485
(DF1)
DH–485
110, 300, 600, 1200, 2400,
4800, 9600, 19.2K
BCC or CRC
NEMA Type 1 (IP30)
45w x 76h x 123d mm
(1.8 x 3.0 x 4.8 in.)
7
Chapter
–GK2
24V DC, 10%
NA
0.4 amps maximum
60mA DC
SCANport Peripheral
Interface
(DF1)
DH–485
4800, 9600, 19.2K
BCC or CRC
NEMA Type 1 (IP30)
45w x 76h x 123d mm
(1.8 x 3.0 x 4.8 in.)
1203–5.5 September 1995