Page 1
ZeroWire Mobile® USER MANUAL U.S. ONLY - ENGLISH...
Page 3
Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. This document is subject to change without notice. NDS provides this information as reference only. Reference to products from other vendors does not imply any recommendation or endorsement.
Safety Information Warnings and Cautions This symbol alerts the user that important information regarding the installation and/or operation of this equipment follows. Information preceded by this symbol should be read carefully. This symbol warns the user that un-insulated voltage within the unit may have sufficient magnitude to cause electrical shock.
Power Module Safety Symbols Read instructions Conformité Care should be Waste Electrical and for use before Européenne taken when using Electronic Equipment using or installing the product. Directive (EU) the product. Recyclable (Taiwan) Conforms to the Federal Underwriters transportation Communications Laboratory (UL) standards for Class 9 Commission...
Note: The Low Charge Level Notification is functionally critical and cannot be disabled. Warning: The ZeroWire Mobile should not be used with medical equipment that poses a safety risk to patients if battery power is lost, or the audible notification is not recognized.
(three LED bars). Regular use of the power modules are recommended to maintain optimum performance. If the power module does not turn on when placed onto a 4-dock ZeroWire Mobile Charging Station for at least three days continuously, contact NDS Customer Service.
General Specifications The ZeroWire Mobile is designed to provide power to an electrical load and can be used continuously. Note: Specifications are subject to change without notice. Contact factory for current specifications. ZeroWire Mobile The ZeroWire Mobile includes the following: •...
Use only NDS power modules. • To power off the ZeroWire Mobile stand, remove both power modules from the stand docks. • The ZeroWire Mobile stand must be positioned in a location with easy access to the stand docks. Power Module Requirements The capacity of a fully charged power module is 10 Ah.
• Operating relative humidity range for the ZeroWire Mobile should not exceed 20% – 75% (non-condensing). • Operating altitude range for the ZeroWire Mobile should not exceed 0 - 6562 ft (0 – 2000 m), with a pressure range not to exceed 14.65 - 11.75 PSI (101 – 81 kPa).
ZeroWire Mobile Assembly Components of the ZeroWire Mobile stand included in your shipment: 1 Hinged Mounting Plate 2 Top Plate 3 Inner Extrusion Subassembly 4 Outer Extrusion Subassembly 5 M6x16mm Cap Head Screw (2x) 6 M6 Flat Washer (2x) IN G...
Field Replaceable Parts Use only NDS approved power modules and replacement parts, certified for use with the ZeroWire Mobile system. Failure to comply will invalidate your warranty and may present serious dangers. For service, warranty replacement, or purchase of any items in the following list, contact NDS at: Americas: customercare@ndssi.com...
ZeroWire Mobile Stand(s). 2. Determine location of wall studs on which the wall mount bracket will be attached, and determine an ergonomic height for the charging station installation.
• Before use, confirm that both power modules are fully charged and correctly docked. • Do not use or store any part of the ZeroWire Mobile system, including power modules and charger in a location exposed to direct sunlight or sources of direct heat such as fire or a heater.
• Power Cable (P/N 90Z0168) for use with NDS 26" HB–32" monitors (Neutrik connector) • ZeroWire Mobile wall power module charger, 4-bay (P/N: 30H0001)with • ZeroWire Mobile power one each United States and European power cord module (P/N 30H0006)
1. Remove the monitor cable cover. 2. Connect the monitor DC power cable first to the ZeroWire Mobile DC output connector, and then to the monitor DC input connector, with the power cable passing between the release lever and monitor.
ZeroWire Mobile Monitor Setup Height Adjustment of Monitor The ZeroWire Mobile supports approximate monitor heights as measured from the axis of the mounting plate hinge to the floor surface ranging from 53.94" – 68.2" (137 cm - 173 cm). To raise and lower the monitor...
5. Firmly grasp the upper and lower handles and push the ZeroWire Mobile in the intended direction. Locked Unlocked Apply Caster Brake Locks 6. When the ZeroWire Mobile has been relocated, prevent accidental movement of the unit by applying the caster brake locks. 16 | ZeroWire Mobile Transport...
2.5 hours to fully charge. After initial charging, charge levels of each power module are monitored, and charging is resumed if self-discharging drops a charge level below 95%. It is recommended that only fully charged power modules be installed for use on the ZeroWire Mobile. Charging Station Specifications...
The power module must be prepared before being placed on a ZeroWire stand. 1. Place the power module on a 4-dock ZeroWire Mobile Charging Station until the blue LED light turns on and all LED bars are indicating fully charged.
Warning: If the Service indicator is illuminated or continues to flash after a reset, remove the power module from use and contact NDS Customer Service. Note: When undocked, the Service indicator of a failed power module will flash when the power switch is pressed.
Page 26
LED bars). Regular use of the power modules is recommended to maintain optimum performance. If the power module does not turn on when placed onto a 4-dock ZeroWire Mobile Charging Station for at least three days continuously, contact NDS Customer Service.
Slot Base The ZeroWire Mobile Stand automatically selects the active power module to supply power to the output. If a depleted power module is removed for charging and a power module with available capacity remains installed, the system will switch to the remaining power module with uninterrupted discharge.
Using nonmetallic flat head screwdriver, carefully pry off the port cover to access the port and avoid scratching the plastic surface. Using the adhesive on the back of the label, the NDS Label can be temporarily placed on the base of the stand. Do not apply too much pressure to make it difficult to remove later.
Page 29
The external charger. External charger power cord. (Note: The plug may vary depending on region.) External Charger | 23...
Electromagnetic Compatibility Tables WARNING: All medical electronic devices must conform to the requirements of IEC 60601-1-2. Precautions, adherences to the Electromagnetic Compatibility (EMC) guideline information provided in this manual and verification of all medical devices in simultaneous operation are required to ensure the electromagnetic compatibility and co-existence of all other medical devices prior to a surgical procedure.
Electromagnetic Immunity Guidance and Manufacturer's Declaration: Electromagnetic Immunity This product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment. Immunity Test Test Level Professional Healthcare Electrostatic discharge (ESD) IEC 61000-4-2 ±2, ±4, ±6, ±8kV contract discharge...
Recommended Separation Distances Recommended Separation Distances Between Portable/Mobile RF Communications Equipment and the Product This product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this product can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the product as recommended below, according to the maximum output power of the communications equipment.
Terms and Conditions Declarations of Conformity FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 2017/745 Medical Device Regulation of European Union. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable results.
NDS neither assumes nor authorizes any person to assume for it any other liabilities in conjunction with and/or related to the sale and/or use of its products. To ensure proper use, handling and care of NDS products, customers should consult the product specific literature, instruction manual, and/or labeling included with the product or otherwise available.
Page 38
Tokyo 140-0013 Japan +81 3 5753 2466 info@ndssi.com Oriental Media Center Suite 2302, Tower C No.4, Guang Hua Road Chao Yang District Beijing, 100026 China +86 10 8559 7859 info@ndssi.com NDS Quality System ISO 13485 FDA Registration #2954921 60A0785 Rev D...