When the system power is on and the SATA HDD is well connected, the activity LED
glows steady green. If it fails to light up, check the SATA connection. Or please ask a
technician to inspect the related cables in the chassis.
当系统电源接通且 SATA HDD 连接良好时,Activity LED 为绿灯亮。如果灯未亮,请
检查是否已将 SATA HDD 连接好。或者请咨询技术人员检查机箱内电缆是否连接好。
當系統電源接通且 SATA HDD 連接良好時,Activity LED 為綠燈亮。如果燈未亮,請
檢查是否已將 SATA HDD 連接好。或者請諮詢技術人員檢查主機殼內電纜是否連接好。
The Rear Panel/ 后面板 / 後面板
3.2
The rear plate includes 1-slot I/O bracket and a motherboard I/O opening. (see Fig-
ure 3.3).
后面板带有 1 槽 I/O 支架和 1 个母板 I/O 开口 (如图 3.3 所示) 。
後面板帶有 1 槽 I/O 支架和 1 個主機板 I/O 開口 (如圖 3.3 所示) 。
There is a ground screw with a washer located on the lower right of the rear panel;
when properly grounded, it protects the system in case of electric leakage.
后面板的右下方带有 1 个带垫圈的地脚螺钉,可以保护系统免受漏电损坏。
後面板的右下方帶有 1 個帶墊圈的地腳螺釘,可以保護系統免受漏電損壞。
Replacing the Cooling Fan/ 更换风扇 / 更換風扇
3.3
There are three system cooling fans behind the front plate of the chassis.
机箱带有 3 个系统冷却风扇,分别位于机箱前面板后。
主機殼帶有 3 個系統冷卻風扇,分別位於主機殼前面板後。
Replacing the system cooling fan/ 更换系统冷却风扇 / 更換系統
3.3.1
冷卻風扇
1.
Unplug fan power connectors.
2.
Unscrew the 4 screws on the fan bracket. Take out the fan bracket carefully.
(See Figure 3.4)
3.
Remove the four screws on the failed fan unit and take out the fan.
4.
Fasten a new fan onto the fan bracket.
5.
Plug in fan power connectors.