Fig. 7-16:Technical Data 115/230 Vac Connection - Bosch REXROTH VSB 40.1 Project Planning Manual

Hide thumbs Also See for REXROTH VSB 40.1:
Table of Contents

Advertisement

VSB 40.1
230/115 VAC Power Supply
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
This connection is used for device variants for 230/115 VAC.
All internally required voltages are generated by the 230/115 VAC power
supply unit.
The supply voltage must comply with
overvoltage category II! Otherwise the
integrated power supply unit might be
destructed.
CAUTION
⇒ Use an isolating transformer to generate the
230/115 VAC (see following page).
The 230/115 VAC connection occurs via a 3-pin inlet connector for AC
connectors on the connector panel. The maximum cable cross section for
the connected cables is 1.5 mm
X20
PE
Fig. 7-15:
Pin assignment of the 230/115 VAC connection X20
Parameters
Rated voltage
Power consumption for U
N
Power consumption for U
N
Inrush current for 264 VAC
Overload protection
Short-circuit protection
Fig. 7-16:
Technical data 115/230 VAC connection
2
.
Value
85 VAC ... 264 VAC auto range
= 230 VAC
2.5 A
= 115 VAC
5 A
100 A
As of 135 %, deactivation
At all outputs, deactivation
7-13
PC Box
Assignment
N1
PE
U2
230V_Buchse.cdr