7-4
PC Box

Parallel Interface XLPT

XLPT – Parallel Interface for
Printer, Scanner, etc.
1
14
D-Sub female connector, 25-pin
Type:
Cable length:
Cable type:
Interrupt (IRQ):
I/O address:
13
25
Fig. 7-4:
LPT interface
The parallel interface normally runs in the standard mode SPP.
Furthermore, it can be operated in the EPP mode (Enhanced Parallel
Port) or in the ECP mode (Extended Capabilities Port), if the suitable
peripheral equipment is available. The mode can be changed in the BIOS
settings.
SPP (ex works), EPP, ECP
3 m max.
Shielded, cross section min. 0.14 mm²
7
AUTO or 378H (recommended)
XLPT
Interface mode
max. 3m
EPP
SPP
1
Write
STROBE
2
Data0
Data0
3
Data1
Data1
4
Data2
Data2
5
Data3
Data3
6
Data4
Data4
7
Data5
Data5
8
Data6
Data6
To peripheral
9
devices
Data7
Data7
10
Intr
ACK
11
Wait
BUSY
12
n.u.
PAPER out
13
n.u.
SEL out
14
Datastb
AUTOFD
15
n.u.
ERROR
16
n.u.
INIT
17
Addrstrb
SEL in
18
GND
GND
19
GND
GND
20
GND
GND
21
GND
GND
22
GND
GND
23
GND
GND
24
GND
GND
25
GND
GND
Shield applied to the metal housing
of the plug-in connector
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
VSB 40.1
Parallel_sst.cdr

Advertisement