VSB 40.1

Serial Interface XCOM

XCOM - Serial interface

Settings of the Serial Interface

Control Panel
DOK-SUPPL*-VSB*40.1***-PR02-EN-P
A serial standard interface is provided at connection XCOM.
D-Sub male connector,
9-pin
Type:
Cable length:
Cable type:
Transmission rate:
Handshake:
Interrupt (IRQ):
I/O address:
BIOS presettings:
1
6
Fig. 7-3:
Pin assignment COM
Note:
Depending on the design, the UPS available as accessory this
interface might be needed for the communication with the
UPS.
To find out settings of the transfer parameters for the serial interfaces,
please refer to the description of the installed operating system (for
Windows under Settings/Control Panel, ...").
BIOS
The standard BIOS setting of COM (Serial Port A) is AUTO (automatic
parameter assignment). Apply the following settings if the parameter
should be assigned directly:
• COM = 3F8H
Note:
Interrupt (IRQ) and I/O address must coincide with the settings
made in BIOS.
RS232
15 m max.
Shielded, cross section min. 0.14 mm²
Max. 115200 bits/s
Hardware and software handshake (XON, XOFF)
4
AUTO (or 3F8H)
Enabled
XCOM
5
9
Shield applied to the metal housing
of the plug-in connector
7-3
PC Box
1
2
3
4
5
6
7
8
9
Com_sst.FH9