Fixture Cleaning: Due to fog residue, smoke, and dust, cleaning the internal and external optical
lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency
will depend on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In
heavy club use, cleaning on a monthly basis is recommended. Periodic cleaning will ensure longevity
and crisp output.
Use normal glass cleaner and a soft cloth to wipe down the outside casing.
Use a brush to wipe down the cooling vents and fan grill.
Clean the external optics and mirror with glass cleaner and a soft cloth every 20 days.
Clean the internal optics with glass cleaner and a soft cloth every 30-60 days.
Always be sure to dry all parts completely before plugging the unit back in.
Vizi Beam 5RX
Below is a common problem that you may encounter, with possible solutions.
No light output from the unit:
Make sure the external fuse has not blown. The fuse is located on the bottom panel of the unit.
Remove the lamp holder and be sure the lamp is fully seated in its socket. Occasionally lamp
connections may loosen during shipping.
Be sure the fuse holder is fully seated.