Page 1
Installation, Operation & Maintenance Manual Submersible Solids Handling Pumps 2BSE-SS & 3BSE-SS 0.5, 0.75 & 1 HP @ 1750 RPM barmesa.com 2BSE51SS 0.5 HP 3BSE102SS 3BSE103SS 2BSE72SS 3BSE104SS 2BSE73SS 1 HP 2BSE74SS 0.75 HP IMPORTANT! - Read all instructions in this manual before operating or servicing a pump.
IMPORTANT! - Barmesa Pumps is not systems, that are required to reduce installations where there is responsible for losses, injury or the potencial for property damage.
0.75" 3BSE104SS* 62180510 1750 14/4 0.75" - 3" discharge flange is available for these models, (this change the model to 3BSE-SS). * 2" discharge flange is available for these models, (this change the model to 2BSE-SS). 12.937" 12.637" 4.875" 6.5"...
Recommendations and Warnings 4Receiving inspection 4 Installation 4Liquid Level Controls Upon receiving the pump, it should These pumps are recommended for The level control(s) should be inspected damage use in a sump, basin or lift station. mounted on the discharge piping, a shortages.
Installation & Service a) Inspect motor chamber for oil level IMPORTANT! - The overload will then automatically reset and start the and contamination. pump up after the motor cools to a b) Inspect impeller and body for safe temperature. In the event of an excessive build-up or clogging.
Page 6
Service 5. Remove v-gasket (23) and replace if Pressure Test (If oil has been Pressure builds up extremely damaged. drained) - Remove pipe plug (34) fast, increase pressure by from housing (3). Apply pipe sealant "TAPPING" air nozzle. Too to pressure gauge assembly and much pressure will damage Motor and Capacitor: tighten into hole.
Page 7
Service Shaft Seal: 4. Place seal’s (24) retaining ring and 9. Place socket head screws (31) 14. Lift motor rotor, shaft, bearing (6), through seal plate into motor housing spring onto shaft. Lightly oil (Do not rotating member of seal, washer (7) and torque to 60 inch pounds.
Page 8
Service SINGLE-PHASE 115/230V AC THREE-PHASE 208/230V AC THREE-PHASE 460V AC POWER CORD 3x14 POWER CORD 4x12 POWER CORD 4x12 G L1 G L1 L2 L2 L3 CAPACITOR T2 T3 T4 T7 T5 T8 T6 T9 G T1 T7 T2 T8 T3 T9 T4 T5 T6 G T1 T2 MOTOR LEADS MOTOR LEADS...
Page 9
Repair Parts Figure 5 barmesa.com For Repair Part Please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Page 10
Parts List ITEM DESCRIPTION QTY. MATERIAL CABLE ASSEMBLY (14AWG-3) O-RING Ø45 x 3.1 NBR 40 PUMP BODY HT200 CAPACITOR 30µ F/300V 90°C ALUMINIUM UPPER BEARING PLATE ZL102 BEARING 6203 WAVE WASHER 65Mn TEMPERATURE PROTECTOR STATOR 10 ROTOR COMPONENT 11 STATOR COMPONENT 12 HEX.
(10) plugged. NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Barmesa Pumps or its authorized service centers, automatically voids warranty.
Page 12
(15) or rigid. NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Barmesa Pumps or its authorized service centers, automatically voids warranty.