Barmesa Pumps 8BSE-HADS Installation, Operation & Maintenance Manual

Barmesa Pumps 8BSE-HADS Installation, Operation & Maintenance Manual

Submersible non-clog sewage pumps

Advertisement

Quick Links

8BSE-HADS
30, 40, 50, 60, 75
@ 1150 RPM
100, 125, 200
barmesapumps.com
@ 1750 RPM
IMPORTANT! - Read all instructions in this manual before operating or servicing
a pump.
Installation, Operation &
Maintenance Manual
Submersible Non-Clog
Sewage Pumps

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8BSE-HADS and is the answer not in the manual?

Questions and answers

Summary of Contents for Barmesa Pumps 8BSE-HADS

  • Page 1 Installation, Operation & Maintenance Manual Submersible Non-Clog Sewage Pumps 8BSE-HADS 30, 40, 50, 60, 75 @ 1150 RPM 100, 125, 200 barmesapumps.com @ 1750 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a pump.
  • Page 2: General Safety Information

    IMPORTANT! - Barmesa Pumps is not systems, that are required to reduce installations where there is responsible for losses, injury or the potencial for property damage.
  • Page 3: Specifications And Dimensions

    Specifications & Dimensions DISCHARGE: 8", 125lb, flange horizontal. SPHERICAL SLD HNDLG: 3" LIQUID TEMPERATURE: 104° F (40° C) max. VOLUTE: Cast iron ASTM A-48 class 30. WEAR RING: Bronze. MOTOR HOUSING: Cast iron ASTM A-48 class 30. SEAL PLATE: Cast iron ASTM A-48 class 30. IMPELLER: 3 vanes , closed, with a bronze wear ring and vanes on back side.
  • Page 4: Recommendations And Warnings

    Recommendations and Warnings Receiving inspection  Installation Liquid Level Controls Upon receiving the pump, it should These pumps are recommended for The level control(s) should be inspected damage use in a sump, basin or lift station. mounted on the discharge piping, a shortages.
  • Page 5: Installation & Service

    Installation & Service Overload Protection: If current through the temperature Plate 3.   Name Record Three Phase - The Normally Closed sensor exceeds the values listed, an information from the pump name intermediate control circuit relay plate to drawing in front of manual (N/C) thermal sensor is embedded in must be used to reduce the current for future reference.
  • Page 6 Service THREE-PHASE 460V AC Clean out the pump body, if Install impeller and motor assembly necessary, examine wear ring (13) onto volute (12). Apply thread L2 L3 and replace if worn. If the wear ring locking compound to threads of each requires replacing, split the wear ring cap screw (2).
  • Page 7: Repair Parts

    Repair Parts Figure 3 SHAFT KEY barmesapumps.com PART LIST ITEM PART No. DESCRIPTION QTY. RELIANCE MOTOR 91010015 LOCKWASHER 5/8" STAINLESS 8-16 91010355 CAP SCREW 5/8" x 2" STAINLESS MOTOR GASKET 03020022 ADAPTER 91010396 SOCKET HD SCREW 5/8" x 1½" STAINLESS 30400105 MOTOR ADAPTER 03140107 IMPELLER 30400415 IMPELLER WASHER...
  • Page 8: Troubleshooting Chart

    13. Piping attachments to building structure too loose or rigid NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Barmesa Pumps or its authorized service centers, automatically voids warranty.