Installation, Operation & Maintenance Manual Submersible Solids Handling Pumps 2BSE411 2BSE511 SERIES 0.4 & 0.5 HP barmesa.com @ 1750 RPM IMPORTANT! - Read all instructions in this manual before operating or servicing a pump. Last update: 12/03/2020...
IMPORTANT! - Barmesa Pumps is not systems, that are required to reduce installations where there is responsible for losses, injury or the potencial for property damage.
Specifications & Dimensions DISCHARGE: 2" NPT female, vertical. SPHERICAL SLD HNDLG: 2" LIQUID TEMPERATURE: 104° F (40° C) max. VOLUTE: Cast iron ASTM A-48 class 30. MOTOR HOUSING: Cast iron ASTM A-48 class 30. SEAL PLATE: Cast iron ASTM A-48 class 30. IMPELLER: Open, double vane.
Recommendations and Warnings 4Receiving inspection 4 Liquid Level Control Upon receiving the pump, it should Typical Discharge Pipe Mounted: inspected damage Refer to Figure 2 below which shows shortages. If damage has occurred, a typical installation of a 1 phase 115 file a claim immediately with the volt pump using a level control company that delivered the pump.
Installation & Service Both a check valve and a shut-off WARNING DO NOT ALLOW THE 5. Pump-Down Test - Be sure pump valve are recommended for each has been properly wired, lowered PUMP TO CYCLE OR RUN IF AN pump. The check valve is used to into the basin, sump or lift station, OVERLOAD CONDITION OCCURS.
Page 6
Service 4Disassembly If oil is found to be clean and Ÿ Impeller, V-ring and Volute: uncontaminated (measuring 1. Disconnect power. above 15 kV breakdown), refill the housing. Ÿ If oil is found to be dirty or Remove capscrews contaminated measures lockwashers, vertically lift motor below 15 kV breakdown), the housing and seal plate assembly from...
Page 7
Service 11. Inspect motor winding for shorts 3. Place seal’s retaining ring, spring 11. Clean the threads with thread and check resistance values. Check locking compound cleaner. Apply onto shaft. Lightly oil (Do not use rotor for wear. If rotor or the stator removable Loctite®...
Page 8
Repair Parts barmesa.com For Repair Part Please supply: Model Number and Serial as shown on Name Plate, and Part Description and Part Number as shown on Parts List.
Page 9
Parts List ITEM DESCRIPTION QTY. MATERIAL CABLE ASSEMBLY (14AWG-3) PUMP BODY HT200 CAPACITOR 25µF/370V 90 °C ALUMINIUM CAPACITOR SET NBR40 UPPER BEARING PLATE ZL102 BEARING 6201 WAVE WASHER 65Mn TEMPERATURE PROTECTOR STATOR 10 ROTOR COMPONENT 11 STATOR COMPONENT STEEL 12 HEX. HEAD BOLT 5/16"-18UNC x 63 SS 304 13 SPRING WASHER SS 304...
13. Piping attachments to building structure too loose or rigid NOTE: Barmesa Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Barmesa Pumps or its authorized service centers, automatically voids warranty.