ADTRAN NetVanta 1560-24-370W Quick Start Manual page 3

24-port managed gbe 370w poe+ switch
Table of Contents

Advertisement

Mounting on a Desk or Shelf
To mount the switch on a desk or shelf, complete the following steps.
1. Verify that the desk or shelf is sturdy enough to support the switch.
2. Attach the four adhesive rubber feet to the bottom of the switch.
f
CAUTION!
Desk, shelf, or wall mounting of the equipment should be such that the amount of air flow required for safe operation of the equipment is not compromised. Allow 1-inch
clearance on the top and sides of the unit for sufficient air flow.
Mounting on a Wall
To mount the switch on a wall, complete the following steps.
1. Using the mounting holes on the bottom of the unit as a template, install four #8 PAN head screws (0.75-inch), using two for each bracket as shown in
appropriate location on the wall. Be aware of the dimensional limitations of the screws.
2. Slide the keyed insets on the bottom of the unit's chassis securely onto the screws.
f
CAUTION!
The NetVanta 1560-24-370W must be mounted in the face down orientation when wall mounted.
g
NOTE
The wall mount brackets are not supplied with the unit and must be purchased separately from ADTRAN, part number 1700520F1.
617101564PF2-13A
Figure 5. Attaching the Rubber Feet
Figure 6. Install Screws in the Wall and Hang the Switch on the Screws
Figure
6, in the
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

17101564pf2

Table of Contents