Download Print this page

SMC Networks ITV0000 Series Manual page 9

Lectro-pneumatic regulator/ electronic vacuum regulator
Hide thumbs Also See for ITV0000 Series:

Advertisement

ITV001m Series
Linearity, Hysteresis
1
0.8
0.6
0.4
0.2
0
–0.2
–0.4
–0.6
–0.8
–1
0
25
Input signal [% F.S.]
Pressure Characteristics
1
0.5
0
–0.5
–1
0.15
0.16
0.17
Supply pressure [MPa]
ITV003m Series
Linearity, Hysteresis
1
0.8
0.6
0.4
0.2
0
Out
–0.2
–0.4
–0.6
–0.8
–1
0
25
Input signal [% F.S.]
Pressure Characteristics
1
0.5
0
–0.5
–1
0.2
0.3
0.4
0.5
Supply pressure [MPa]
Compact Electro-Pneumatic Regulator
Return
Out
50
75
Set pressure: 0.05 MPa
Out
Return
0.18
0.19
Return
50
75
Set pressure: 0.25 MPa
Out
Return
0.6
0.7
0.8
0.9
Repeatability
1
0.5
0
–0.5
–1
100
1
Flow Rate Characteristics
120
100
80
60
40
20
0
0.20
0
0.5
Repeatability
1
0.5
0
–0.5
–1
100
1
Flow Rate Characteristics
600
500
400
300
200
100
0
1.0
0
1
ITV0000
With 50% of signal input
2
3
4
Count
Supply pressure: 0.2 MPa
100 kPa
80 kPa
60 kPa
40 kPa
20 kPa
10 kPa
1
1.5
2
2.5
3
Flow rate [L/min (ANR)]
With 50% of signal input
2
3
4
Count
Supply pressure: 0.6 MPa
500 kPa
400 kPa
300 kPa
200 kPa
100 kPa
50 kPa
2
3
4
5
Flow rate [L/min (ANR)]
Series
5
3.5
4
5
6
7
8

Advertisement

loading
Need help?

Need help?

Do you have a question about the ITV0000 Series and is the answer not in the manual?