 Please check and test emergency stop circuits after wiring. (Installer is responsible for
the correct wiring.)
 Never touch any of the input or output power lines directly or allow any input of output
power lines to come in contact with the inverter case.
 Do not perform a dielectric voltage withstand test (megger) on the inverter this will result
in inverter damage to the semiconductor components.
Caution
 The line voltage applied must comply with the inverter's specified input voltage.
 Connect braking resistor and braking unit to the designated terminals.
 Do not connect a braking resistor directly to the DC terminals P (+) and N (-), otherwise
fire may result.
 Use wire gauge recommendations and torque specifications.
 Never connect input power to the inverter output terminals U/T1, V/T2, W/T3.
 Do not connect a contactor or switch in series with the inverter and the motor.
 Do not connect a power factor correction capacitor or surge suppressor to the inverter
output.
 Ensure the interference generated by the inverter and motor does not affect peripheral
devices.
1.3

Before Operation

Warning
 Make sure the inverter capacity matches the parameters 13-00.
 Reduce the carrier frequency (parameter 11-01) If the cable from the inverter to the
motor is greater than 80 ft (25m). A high-frequency current can be generated by stray
capacitance between the cables and result in an overcurrent trip of the inverter, an
increase in leakage current, or an inaccurate current readout.
 Be sure to install all covers before turning on power. Do not remove any of the covers
while power to the inverter is on, otherwise electric shock may occur.
 Do not operate switches with wet hands, otherwise electric shock may result.
 Do not touch inverter terminals when energized even if inverter has stopped, otherwise
electric shock may result.
1.4

Parameters Setting

Caution
 Do not connect a load to the motor while performing a rotational auto-tune.
 Make sure the motor can freely run and there is sufficient space around the motor
when performing a rotational auto-tune.
1.5
Operation
Warning
 Be sure to install all covers before turning on power. Do not remove any of the covers
while power to the inverter is on, otherwise electric shock may occur.
 Do not connect or disconnect the motor during operation. This will cause the inverter
to trip and may cause damage to the inverter.
 Operations may start suddenly if an alarm or fault is reset with a run command
active. Confirm that no run command is active upon resetting the alarm or fault,
otherwise accidents may occur.
 Do not operate switches with wet hands, otherwise electric shock may result.
 It provides an independent external hardware emergency switch, which emergently shuts
down the inverter output in the case of danger.
 If automatic restart after power recovery (parameter 07-00) is enabled, the inverter will