Download Print this page

Advertisement

Quick Links

FM50(TW/ E2)
 
Start Guide for FM50 series Inverters
& motors
This guide is to assist you in installing/ running the inverter and
verify that it is functioning correctly for the main and basic features
of Inverter.
For detailed information and if there are any doubts please refer to
the instruction manual.
Supply & Motor connection
1) Ensure that the Inverter & the motor have the correct
KW power and voltage ratings.
Motor full load amps must not exceed the Inverter rating.
2) Ensure that the Supply & Motor cables are connected
correctly prior to switch on.
3) For single phase supply, use L1(L) & L3(N) on units
which has 3 supply terminals.
On units with two supply terminals L1&L2, connect the
live to L1 and the Neutral to L2.
4) Connect motor cable to terminals T1, T2 & T3.
(Swap any two leads if motor runs in reverse direction).
5) Connect both supply & motor Earth to the drive Earth
terminal tag strips, screw this to the bottom left case
screw.
FM50(TW/ E2)- START GUIDE
 
 
START GUIDE
1
 

Advertisement

loading
Need help?

Need help?

Do you have a question about the FM50 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TECO FM50 Series

  • Page 1   FM50(TW/ E2)   START GUIDE Start Guide for FM50 series Inverters & motors This guide is to assist you in installing/ running the inverter and verify that it is functioning correctly for the main and basic features of Inverter.
  • Page 2: Apply Power To The Drive

                                                                                                                       Apply power to the drive Apply power to the drive. The display will be flashing and showing 05.0 This is the default (factory setting) frequency. If the unit has been used then it will show the last frequency programmed.
  • Page 3   Remote speed reference and Remote run Wiring for Remote mode 1) Ensure that you have carried out installation & wiring requirements as per step1 quick start guide on previous page before you proceed. 2) Check the position of SW1. Down position for 0-10Vdc. Up position for 4-20mA input.
  • Page 4                                                                                                                Check/ verify and change parameters Check / verify and change parameters for remote start & remote frequency as necessary before you proceed. Parameters F10 & F11 See “Basic quick start parameter list” & “How to change parameters”. RUN using remote speed reference. (Potentiometer, 0- ...
  • Page 5   the word END will be displayed. 5) Use key to select the next parameter to change and follow Steps 2 to 4 until all changes are complete. 6) Pressing the DSP/FUN key repeatedly will alternate the display between the preset frequency (flashing display) and the last parameter accessed.
  • Page 6 010: 50Hz system 010/ 020 020: 60Hz system Note: 1. For Full Parameter List see the Instruction manual, this can be downloaded at TECO Australia Ltd. Website http://www.teco.com.au 2. The Parameter with blue color is frequently used. FM50(TW/ E2)- START GUIDE  ...
  • Page 7: Interconnection Diagram

      Interconnection Diagram *(note)Braking Resister (Option) L1 (L) (U)T1 AC Input (V)T2 L3 (N) (W)T3 Trip Relay Multi-Function Inputs CON2 Test Points +10V Speed Pot 10k (0~10V/0~20/4~20mA) Grounding 0V(FM–) 0~10V NOTES: 1) On 0.75Kw 240V Single phase L1& L2 is available only for Connection.
  • Page 8                                                                                                                Our all ranges of INVERTERS are designed as a motor control and you should always connect the output direct to a motor. Do use a fixed connection to the AC power line.  DO put a three phase motor directly on the U, V, W or T1, T2, ...
  • Page 9   DO NOT put any switches or contacts on the U,  V, W or T1, T2, T3 terminals. DO NOT put a DC motor on the U, V, W or T1,  T2, T3 terminals. DO NOT put any lamps or transformers on the ...
  • Page 10 380V to 415V phase to phase. How to determine the motor configuration? Connection On the left is a typical TECO & MONARCH motor terminal arrangement.      The drawing shows the Star configuration. The three wires from the Inverter output terminals directly to the U1, V1 and W1 leads.
  • Page 11 Inverter. IF YOU HAVE ANY DOUBT ABOUT THE WIRING OF YOU INVERTER PLEASE CONTACT US FOR TECHNICAL ASSISTANCE, WE WILL BE HAPPY TO ASSIST YOU. You can visit TECO website http://www.teco.com.au/ for more information. FM50(TW/ E2)- START GUIDE  ...
  • Page 12: Australia And New Zealand

    Fax: 03 9720 5355 Brisbane Perth Tel: 07 3373 9600 Tel: 08 9479 4879 Fax: 07 3373 9699 Fax: 08 9478 3876 New Zealand Tel: 64 9-526 8480 Fax: 64 9-526 8484 sales@teco.co.nz 10_03_10 FM50(TW/ E2)- START GUIDE      ...