Photon Focus MV1-D3360 Series User Manual page 106

Cmos camera with gige interface
Table of Contents

Advertisement

7 Software
7.9.4 PLC Settings for A/B Trigger from single-ended inputs
This configuration maps the single-ended inputs to the A/B camera inputs: ISO_IN0 is mapped
to the A signal and ISO_IN1 to the B signal see Table 7.3 (the visibility in the PF_GEVPlayer must
be set to Guru for this purpose).
The AB Trigger feature is not available on all camera revisions, see Appendix B
for a list of available features.
Feature
TriggerMode
TriggerSource
PLC_I0
PLC_I1
PLC_Q6_Variable0
PLC_Q6_Operator0
PLC_Q6_Variable1
PLC_Q6_Operator1
PLC_Q6_Variable2
PLC_Q6_Operator2
PLC_Q6_Variable3
PLC_Q7_Variable0
PLC_Q7_Operator0
PLC_Q7_Variable1
PLC_Q7_Operator1
PLC_Q7_Variable2
PLC_Q7_Operator2
PLC_Q7_Variable3
Table 7.3:
PLC Settings for A/B Trigger from single-ended inputs (<PLC> = in category
IPEngine/ProgrammableLogicController)
.
106 of 125
Value
Category
On
AcquisitionControl
ABTrigger
AcquisitionControl
Line0
<PLC>/SignalRoutingBlock
Line1
<PLC>/SignalRoutingBlock
PLC_I0
<PLC>/LookupTable/Q6
Or
<PLC>/LookupTable/Q6
Zero
<PLC>/LookupTable/Q6
Or
<PLC>/LookupTable/Q6
Zero
<PLC>/LookupTable/Q6
Or
<PLC>/LookupTable/Q6
Zero
<PLC>/LookupTable/Q6
PLC_I1
<PLC>/LookupTable/Q7
Or
<PLC>/LookupTable/Q7
Zero
<PLC>/LookupTable/Q7
Or
<PLC>/LookupTable/Q7
Zero
<PLC>/LookupTable/Q7
Or
<PLC>/LookupTable/Q7
Zero
<PLC>/LookupTable/Q7
MAN071 12/2018 V1.1